PC123/PC123F
PC123/PC123F
s
Features
1. Conform to European Safety Standard
2. Internal isolation distance : 0.4mm or more
3. High collector-emitter voltage ( V
CEO
: 70V)
4. Long creepage distance type
5. Recognized by UL (No. E64380)
Approved by VDE ( DIN-VDE83601 )
Approved by BSI
( BS415 No. 7087, BS7002 No. 7409 )
Approved by SEMCO ( No. 9216212 )
Approved by DEMCO ( No. 108954 )
Approved by NEMKO ( No. 199438181 )
Approved by EI ( No. 155030 )
Recognized by CSA (No. CA95323)
PC123
PC123F
Creepage distance
6.4mm or more
8mm or more
Space distance
6.4mm or more
8mm or more
European Safety Standard
Approved Type Long Creepage
Distance Photocoupler
s
Outline Dimensions
PC123
Anode mark
1
2
1
PC123
1.2
±
0.3
1.0
±
0.1
2
6.5
±
0.3
7.62
±
0.3
3
4.58
±
0.3
3.5
±
0.5
0.5
±
0.1
3.4
±
0.5
g
DIN-VDE0884 approved type
( PC123Y/PC123FY )
is also available as an option.
( Unit : mm )
Internal connection diagram
4
3
1
2
3
4
Anode
Cathode
Emitter
Collector
4
2.54
±
0.25
4.58
±
0.3
Internal connection diagram
1
2
4
3
1
2
3
4
Anode
Cathode
Emitter
Collector
4
PC123
4.58
±
0.3
4.58
±
0.3
3.5
±
0.5
Epoxy resin
0.26
±
0.1
0.5
±
0.1
2.54
±
0.25
3
3.05
±
0.5
Epoxy resin
0.26
±
0.1
PC123F
Anode mark
s
Applications
1. Power supplies
2. OA equipment
1
1.2
±
0.3
1.0
±
0.1
s
Absolute Maximum Ratings
Parameter
Forward current
*1
Peak forward current
Input
Reverse voltage
Power dissipation
Collector-emitter voltage
Emitter-collector voltage
Output
Collector current
Collector power dissipation
Total power dissipation
*2
Isolation voltage
Operating temperature
Storage temperature
*3
Soldering temperature
Symbol
I
F
I
FM
V
R
P
V
CEO
V
ECO
I
C
P
C
P
tot
V
iso
T
opr
T
stg
T
sol
( Ta = 25˚C )
Ratings
50
1
6
70
70
6
50
150
200
5
- 30 to + 100
- 55 to + 125
260
Unit
mA
A
V
mW
V
V
mA
mW
mW
kV
rms
˚C
˚C
˚C
2
6.5
±
0.3
7.62
±
0.3
2.7
MIN.
10.16
±
0.5
*1 Pulse width <= 100
µ
s, Duty ratio : 0.001
*2 AC for 1 minute, 40 to 60% RH
*3 For 10 seconds
“
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.
”