PC829 Series
PC829 Series
..
s
Features
High Density Mounting Type
Photocoupler
s
Outline Dimensions
PC829
1.2
±
0.3
0.9
±
0.2
8 7 6
PC829
5
6.5
±
0.5
8
7
6
g
TUV ( VDE0884 ) approved type is also available as an option.
( Unit : mm )
Internal connection
diagram
5
0.5TYP.
3.0
±
0.5
3.5
±
0.5
1. Symmetrical terminal configuration
PC829
: 2-channel type
PC849
: 4-channel type
2. High current transfer ratio
( CTR : MIN. 50% at I
F
= 5mA, V
CE
= 5V)
3. High isolation voltage between input and
output ( V
iso
: 5 000V
rms
)
4. Recognized by UL, file No. E64380
1
Anode mark
2
3
4
2.54
±
0.25
1
2
3
4
9.66
±
0.5
7.62
±
0.3
s
Applications
1. Telephone exchangers
2. Computer terminals
3. System appliances, measuring instruments
4. Signal transmission between circuits of
different potentials and impedances
1
2
4
3
0.26
±
0.1
0.5
±
0.1
5
6
1.2
±
0.3
0.9
±
0.2
8
7
Emitter
Collector
θ
θ
=
0 to 13
˚
θ
Anode
Cathode
PC849
16
15
14
13 12
Internal connection
diagram
9
6.5
±
0.5
16 15
14 13
12 11 10
11 10
9
PC849
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Anode mark
19.82
±
0.5
2.54
±
0.25
0.5TYP.
7.62
±
0.3
3.5
±
0.5
3.0
±
0.5
0.26
±
0.1
θ
θ
=
0 to 13
˚
Emitter
Collector
θ
0.5
±
0.1
s
Absolute Maximum Ratings
Parameter
Forward current
*1
Peak forward current
Reverse voltage
Power dissipation
Collector-emitter voltage
Emitter-collector voltage
Collector current
Collector power dissipation
Total power dissipation
*2
Isolation voltage
Operating temperature
Storage temperature
*3
Soldering temperature
Symbol
I
F
I
FM
V
R
P
V
CEO
V
ECO
I
C
P
C
P
tot
V
iso
T
opr
T
stg
T
sol
( Ta = 25˚C )
Unit
mA
A
V
mW
V
V
mA
mW
mW
V
rms
˚C
˚C
˚C
Input
Output
Rating
50
1
6
70
35
6
50
150
170
5 000
- 25 to + 100
- 40 to + 125
260
1
2
4
3
5
6
8
7
Anode
Cathode
9
12 13 16
10 11 14 15
*1 Pulse width<=100µs, Duty ratio : 0.001
*2 40 to 60% RH, AC for 1 minute
*3 For 10 seconds
“ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.”