PC911
PC911
s
Features
1. Ultra-high speed response
( t
PHL
, t
PLH
: TYP. 50ns )
2. High instantaneous common mode rejec-
tion voltage ( CM
H
: TYP. 10kV/
µ
s )
3. High isolation voltage
( V
iso
: 4 000V
rms
)
4. Recognized by UL, file No. E64380
Ultra-high Speed Response and
High CMR OPIC Photocoupler
s
Outline Dimensions
0.85
±
0.3
8
7
6
PC911
1.2
±
0.3
5
6.5
±
0.5
g
Lead forming type ( I type ) and taping reel type ( P type ) are also available. (
PC911I/PC911P
)
( Unit : mm )
Internal connection
diagram
8
7
6
5
Amp
0.8
±
0.2
Primary side mark ( Sunken place )
1
2
3
4
1
2
3
4
s
Applications
1. High speed interfaces for computer periph-
erals and microcomputer systems
2. High speed line receivers
3. Interfaces with various data transmission
equipment
3.7
±
0.5
3.5
±
0.5
0.5
TYP.
9.22
±
0.5
7.62
±
0.3
0.5
±
0.1
2.54
±
0.25
θ
θ
=
0
˚
to 13
˚
0.26
±
0.1
θ
1
2
3
4
NC
Anode
Cathode
NC
5
6
7
8
GND
V
O
V
E
V
CC
* “ OPIC ” ( Optical IC ) is a trademark of the SHARP Corporation.
An OPIC consists of a light-detecting element and signal-
processing circuit integrated onto a single chip.
s
Absolute Maximum Ratings
Parameter
Forward current
Reverse voltage
*1
Power dissipation
Supply voltage
*2
Enable voltage
High level output current
Low level output current
*1
*3
Power dissipation
*4
Isolation voltage
Operating temperature
Storage temperature
*5
Soldering temperature
*1
( Ta = 25˚C )
Symbol
I
F
V
R
P
V
CC
V
E
V
OH
I
OL
P
V
iso
T
opr
T
stg
T
sol
Rating
20
5
40
7
7
- 8
25
40
4 000
0 to + 70
- 55 to + 125
260
Unit
mA
V
mW
V
V
mA
mA
mW
V
rms
˚C
˚C
˚C
Input
Output
*1 Ta = 0 to 70˚C
*2 Shall not exceed 500mV from supply voltage( Vcc ) .
*3 Applicable to output terminal ( V
o
)
*4 AC for 1 minute, 40 to 60% RH
*5 For 10 seconds at the position of 2mm or more from root of lead pins.
“
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.
”