欢迎访问ic37.com |
会员登录 免费注册
发布采购

S202S01 参数 Datasheet PDF下载

S202S01图片预览
型号: S202S01
PDF下载: 下载PDF文件 查看货源
内容描述: SIP型SSR用于中等功率控制 [SIP Type SSR for Medium Power Control]
分类和应用: 功率控制
文件页数/大小: 4 页 / 60 K
品牌: SHARP [ SHARP ELECTRIONIC COMPONENTS ]
 浏览型号S202S01的Datasheet PDF文件第2页浏览型号S202S01的Datasheet PDF文件第3页浏览型号S202S01的Datasheet PDF文件第4页  
S102S01/S102S02/S202S01/S202S02
S102S01/S102S02
S202S01/S202S02
s
Features
1. High radiation resin mold package
2. RMS ON-state current
I
T
: 8 Arms at T
C
<= 80˚C
( With heat sink )
3. Built-in zero-cross circuit
( S102S02/S202S02 )
4. High repetitive peak OFF-state voltage
S102S01/S102S02
V
DRM
: MIN. 400V
S202S01/S202S02
V
DRM
: MIN. 600V
5. Isolation voltage between input and output
( V
iso
: 4 000V
rms
)
6. Approved by CSA, No. LR63705
Recognized by UL, file No. E94758
SIP Type SSR for Medium
Power Control
s
Outline Dimensions
( Unit : mm )
* The metal parts marked *
are common to terminal 1 .
g
Do not allow external connection.
( )
:
Typical dimensions
18.5
±
0.2
16.4
±
0.3
φ
3.2
±
0.2
A ( Model No. )
B
S102S01
8A125VAC
S102S02
S202S01
8A250VAC
S202S02
3.2
±
0.2
5.5
±
0.2
5.0
±
0.3
*
g
0.2
MAX.
A
B
+ -
4.2
MAX.
1
2
3
4
s
Applications
1. Automatic vending machines, programmable
controllers
2. Amusement equipment
(5.08) (7.62)
Internal connection diagram
S102S01
/S202S01
(2.54)
0.6
±
0.1
(1.4)
S102S02
/S202S02
s
Model Line-ups
For 100V lines
For phase control
No built-in zero-cross circuit
Built-in zero-cross circuit
S102S01
S102S02
For 200V lines
S202S01
S202S02
1
2
3
4
1
2
3 4
Zero-Cross
Circuit
1 2
1
2
3
4
3 4
Output ( Triac T2 )
Output ( Triac T1 )
Input (
+
)
Input (
-
)
Output ( Triac T2 )
Output ( Triac T1 )
Input (
+
)
Input (
-
)
s
Absolute Maximum Ratings
Parameter
Input
Forward current
Reverse voltage
*1
RMS ON-state current
*2
Peak one cycle surge current
Repetitive peak OFF-state voltage
Non-repetitive peak OFF-state voltage
Critical rate of rise of ON-state
current
( Ta = 25˚C )
Symbol
I
F
V
R
I
T
I
surge
V
DRM
V
DSM
dI/dt
f
V
iso
T
opr
T
stg
T
sol
Rating
S102S01
S102S02
S202S01
S202S02
Unit
mA
V
A
rms
A
V
V
A/µ s
Hz
V
rms
˚C
˚C
˚C
50
6
8
80
400
400
600
600
Output
Operating frequency
Isolation voltage
Operating temperature
Storage temperature
*4
Soldering temperature
*3
50
45 to 65
4 000
- 25 to + 100
- 30 to + 125
260
*1 T
C
<= 80˚C
*2 50Hz sine wave, T
j
= 25˚C
start
*3 60Hz AC for 1 minute,
40 to 60% RH, Apply voltages
between input and output, by
the dielectric withstand
voltage tester with zero-
cross circuit.
( Input and output shall be
shorted respectively ) .
( Note)
When the isolation voltage
is necessary at using external
heat sink, please use the
insulation sheet.
*4 For 10 seconds
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.”
11.2
MIN.
4
-
1.1
±
0.2
4
-
1.25
±
0.3
4
-
0.8
±
0.2
19.6
±
0.2
(36.0)