S202SE1/S202SE2/S216SE1/S216SE2
S202SE1/S202SE2
S216SE1/S216SE2
s
Features
1. Comforms to European Safety Standard ( EN60950)
( Need of the insulation sheet when mounting external heat sink )
Internal insulation distance : 0.4mm or more
Creepage distance : 5mm or more
Space distance : 4mm or more
2. RMS ON-state current
S202SE1 / S202SE2
: 8Arms at Tc <= 80˚C
( with heat sink )
S216SE1 / S216SE2
: 16Arms at Tc <= 60˚C
( with heat sink )
3. Isolation voltage .between input and output ( V
iso
: 3 000V
rms
)
.
4. Approved by TUV, No. R9051479
5. Recognized by UL, No. E94758
( S202SE1 / S202SE2 )
Approved by CSA, No. LR63705
( S202SE1 , S202SE2 )
SIP Type SSR for Medium
Power Control
s
Outline Dimensions
( Unit : mm )
* The metal parts marked * are common to terminal 1
g
Do not allow external connection.
( )
:
Typical dimensions
18.5
±
0.2
16.4
±
0.3
φ
3.2
±
0.2
A (Model No.)
B
S202SE1
8A260VAC
S202SE2
S216SE1
16A260VAC
S216SE2
3.2
±
0.2
5.5
±
0.2
5.0
±
0.3
*
g
2.0
MAX.
A
B
+ -
4.2
MAX.
1
2
3
4
11.2
MIN.
0.6
±
0.1
4
-
4
-
1.25
±
0.3
4
-
0.8
±
0.2
1.1
±
0.2
19.6
±
0.2
(36.0)
s
Applications
1. Copiers
2. Laser beam printers
(5.08) (7.62)
Internal connection diagram
S202SE1/S216SE1
(2.54)
(1.4)
S202SE2/S216SE2
s
Line-up
RMS ON-state current
MAX. 8Arms MAX. 16Arms
S202SE1
S216SE1
S202SE2
S216SE2
1
2
3
4
zero-cross
circuit
1 2
3 4
( Triac. T2 )
Output
Output ( Triac. T1 )
Input (
+
)
Input (
-
)
1 2
3 4
( Triac. T2 )
Output
Output ( Triac. T1 )
Input (
+
)
Input (
-
)
No built-in
Zero-cross circuit
Built-in
Zero-cross circuit
1
2
3
4
s
Absolute Maximum Ratings
Parameter
Input
Forward current
Reverse voltage
RMS ON-state current
*1
Peak one cycle surge current
Repetitive peak OFF-state voltage
Non-repetitive peak OFF-state voltage
Critical rate of rise of ON-state current
Operating frequency
*2
Isolation voltage
Operating temperature
Storage temperature
*3
Soldering temperature
Symbol
I
F
V
R
I
T
I
surge
V
DRM
V
DSM
dI
T
/dt
f
V
iso
T
opr
T
stg
T
sol
( Ta = 25˚C )
Rating
S202SE1 / S202SE2 S216SE1 / S216SE2
50
6
*5
*4
8
16
80
160
600
600
50
45 to 65
3,000
- 25 to + 100
- 30 to + 125
260
Unit
mA
V
A
rms
A
V
V
A/µ s
Hz
V
rms
˚C
˚C
˚C
Output
*1 60Hz sine wave, T
j
= 25˚C start
*2 AC 60Hz for 1 minute, 40 to 60% RH, Apply voltages between input and output by the dielectric
withstand voltage tester with zero-cross circuit.( Input and output shall be shorted respectively) .
( Note) When the isolation voltage is necessary at using external heat sink, please use the insulation sheet.
*3 For 10 seconds *4 T
C
<=80˚C *5 T
C
<=60˚C
“
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.”