 浏览型号S-35390A-T8T1G的Datasheet PDF文件第9页浏览型号S-35390A-T8T1G的Datasheet PDF文件第10页浏览型号S-35390A-T8T1G的Datasheet PDF文件第11页浏览型号S-35390A-T8T1G的Datasheet PDF文件第12页浏览型号S-35390A-T8T1G的Datasheet PDF文件第14页浏览型号S-35390A-T8T1G的Datasheet PDF文件第15页浏览型号S-35390A-T8T1G的Datasheet PDF文件第16页浏览型号S-35390A-T8T1G的Datasheet PDF文件第17页  
2-WIRE REAL-TIME CLOCK  
S-35390A  
Rev.2.4_00  
3. Status register 2  
Status register 2 is a 1-byte register that is used to display and set various modes. The bit configuration is shown below.  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
B7  
INT1FE  
R/W  
INT1ME  
R/W  
INT1AE  
R/W  
32kE  
R/W  
INT2FE  
R/W  
INT2ME  
R/W  
INT2AE  
R/W  
TEST  
R/W  
R/W: Read/Write  
Figure 13 Status Register 2  
B0 : TEST  
This is a test flag for SII. Be sure to set this flag to “0” in use. If this flag is set to “1”, be sure to initialize to set “0”.  
B1 : INT2AE, B2 : INT2ME, B3 : INT2FE  
These bits are used to select the output mode for the  
pin. Table 10 shows how to select the mode. To use an  
INT2  
alarm 2 interrupt, set alarm interrupt mode, then access the INT2 register.  
Table 10 Output Modes for INT2 Pin  
INT2AE  
0
INT2ME  
INT2FE  
INT2 Pin Output Mode  
0
0
1
1
0
0
1
0
1
0
No interrupt  
*1  
Output of user-set frequency  
Per-minute edge interrupt  
Minute-periodical interrupt 1 (50% duty)  
Alarm 2 interrupt  
*1  
*1  
1
*1. Don’t care (Both of 0 and 1 are acceptable).  
B4 : 32kE, B5 : INT1AE, B6 : INT1ME, B7 : INT1FE  
These bits are used to select the output mode for the  
pin. Table 11 shows how to select the mode. To use  
INT1  
alarm 1 interrupt, access the INT1 register after setting the alarm interrupt mode.  
Table 11 Output Modes for  
Pin  
INT1  
32kE  
INT1AE  
0
INT1ME  
INT1FE  
Pin Output Mode  
INT1  
0
0
0
0
0
0
1
0
0
1
1
0
1
0
1
0
1
0
1
No interrupt  
*1  
Output of user-set frequency  
Per-minute edge interrupt  
Minute-periodical interrupt 1 (50% duty)  
Alarm 1 interrupt  
Minute-periodical interrupt 2  
32.768 kHz output  
*1  
0
1
1
*1  
*1  
*1  
*1. Don’t care (Both of 0 and 1 are acceptable).  
Seiko Instruments Inc.  