Rev.2.2
_00
Recommended Operating Conditions
Parameter
Power Voltage
Input Voltage
Output Voltage
Input Rise and Fall Time
Symbol
V
CC
V
IN
V
OUT
dt/dv
MINI LOGIC SERIES INVERTER
S-75V04ANC
Standard
2 to 5.5
0 to 5.5
0 to V
CC
0 to 100 (V
CC
=3.3±0.3 V)
0 to 20 (V
CC
=5±0.5 V)
Unit
V
V
V
ns/V
DC Characteristics
Parameter
Symbol
Conditions
V
CC
Input
Voltage
"H" level
"L" level
V
IH
V
IL
2.0
3 to 5.5
2.0
3 to 5.5
2.0
I
OH
=-50
µA
"H" level
Output
Voltage
I
OL
=50
µA
"L" level
V
OL
V
IN
=V
IH
I
OL
=4 mA
I
OL
=8 mA
Input Current
Current Consump.
I
IN
I
CC
V
IN
=5.5 V or GND
V
IN
=V
CC
or GND
V
OH
V
IN
=V
IL
I
OH
=-4 mA
I
OH
=-8 mA
3.0
4.5
3.0
4.5
2.0
3.0
4.5
3.0
4.5
0 to 5.5
5.5
MIN.
1.5
V
CC
X0.7
1.9
2.9
4.4
2.58
3.94
Ta=25
°C
TYP.
2.0
3.0
4.5
0
0
0
MAX.
0.5
V
CC
X0.3
0.1
0.1
0.1
0.36
0.36
±0.1
1.0
Ta=-40 to 85
°C
MIN.
1.5
V
CC
X0.7
1.9
2.9
4.4
2.48
3.80
MAX.
0.5
V
CC
X0.3
0.1
0.1
0.1
0.44
0.44
±1.0
10.0
µA
µA
V
V
Unit
Seiko Instruments Inc.
11