 浏览型号S-8232AWFT-T2-G的Datasheet PDF文件第5页浏览型号S-8232AWFT-T2-G的Datasheet PDF文件第6页浏览型号S-8232AWFT-T2-G的Datasheet PDF文件第7页浏览型号S-8232AWFT-T2-G的Datasheet PDF文件第8页浏览型号S-8232AWFT-T2-G的Datasheet PDF文件第10页浏览型号S-8232AWFT-T2-G的Datasheet PDF文件第11页浏览型号S-8232AWFT-T2-G的Datasheet PDF文件第12页浏览型号S-8232AWFT-T2-G的Datasheet PDF文件第13页  
Rev.5.4
_00
BATTERY PROTECTION IC FOR 2-SERIAL-CELL PACK
S-8232 Series
Table 7
Item
Symbol
(Ta
= −
40 to
+85 °C
unless otherwise specified)
Test Test
Condition
Min.
Typ.
Max.
Unit
Condition Circuit
V
CU1, 2
0.055
V
CU1, 2
×
1.19
V
CU1, 2
×
1.05
V
CD1, 2
0.080
V
DD1, 2
0.110
V
DU1, 2
0.130
V
IOV1
0.033
V
CU1, 2
+
0.045
V
CU1, 2
V
CU1, 2
×
1.25
×
1.31
V
CU1, 2
V
CU1, 2
×
1.11
×
1.17
V
CD1, 2
V
CD1, 2
+
0.070
V
DD1, 2
V
DD1 ,2
+
0.100
V
DU1, 2
V
DU1, 2
+
0.120
V
IOV1
V
IOV1
+
0.033
1.20
0
0.05
1.00
100
10
7.5
0.0002
0.71
0.6
0
2.06
141
14.7
18
16
14.2
0.10
V
CU1, 2
V
V
V
V
V
V
V
V
mV/°C
mV/°C
s
ms
ms
V
V
µA
µA
V
V
V
MΩ
kΩ
kΩ
1, 2
1, 2
1, 2
1, 2
1, 2
1, 2
3
3
8, 9
8, 9
10
4
4
6
6
7
7
5
5
1
1
1
1
1
1
1
1
5
5
5
2
2
3
3
4
4
2
2
[DETECTION VOLTAGE]
Overcharge detection voltage 1, 2
Auxiliary overcharge detection voltage 1, 2
*1
V
CUaux1
, V
CUaux2
=
V
CU1
, V
CU2
×
1.25 or
V
CUaux1
, V
CUaux2
=
V
CU1
, V
CU2
×
1.11
Overcharge release voltage 1, 2
Overdischarge detection voltage 1, 2
Overdischarge release voltage 1, 2
Overcurrent detection voltage 1
Overcurrent detection voltage 2
Temperature coefficient 1 for detection voltage
*2
Temperature coefficient 2 for detection voltage
*3
[DELAY TIME (C3
=
0.22
µF)
]
Overcharge detection delay time 1, 2
Overdischarge detection delay time 1, 2
Overcurrent detection delay time 1
[INPUT VOLTAGE]
Input voltage between VCC and VSS
[OPERATING VOLTAGE]
Operating voltage between VCC and VSS
*4
[CURRENT CONSUMPTION]
Current consumption during normal operation
Current consumption at power down
[OUTPUT VOLTAGE]
DO voltage “H”
DO voltage “L”
CO voltage “H”
[CO PIN INTERNAL RESISTANCE]
Resistance between VSS and CO
[INTERNAL RESISTANCE]
Resistance between VCC and VM
Resistance between VSS and VM
[0 V BATTERY CHARGE FUNCTION]
V
CU1, 2
3.85 to 4.60 V,
Adjustable
V
CUaux1, 2
V
CU1, 2
×
1.25
V
CUaux1, 2
V
CU1, 2
×
1.11
V
CD1, 2
3.60 to 4.60 V,
Adjustable
V
DD1, 2
1.70 to 2.60 V,
Adjustable
V
DU1, 2
1.70 to 3.80 V,
Adjustable
V
IOV1
0.07 to 0.30 V,
Adjustable
V
IOV2
Load short circuit,
1.70
V
CC
reference
T
COE1
Ta
= −
40 to
+
85 °C
0.6
T
COE2
Ta
= −
40 to
+
85 °C
0.24
t
CU1, 2
1.0 s
t
DD1, 2
0.1 s
t
IOV1
0.01 s
V
DS
Absolute maximum
rating
0.55
67
6.3
0.3
2.0
1.8
0
V
DSOP
Output logic fixed
I
OPE
I
PDN
V1
=
V2
=
3.6 V
V1
=
V2
=
1.5 V
V
DO(H)
I
OUT
=
10
µA
V
DO(L)
I
OUT
=
10
µA
V
CO(H)
I
OUT
=
10
µA
R
COL
V
CO
V
SS
=
9.4 V
R
VCM
V
CC
V
VM
=
0.5 V
R
VSM
V
VM
V
SS
=
1.1 V
V
CC
V
CC
V
CC
0.17
0.003
V
SS
V
SS
V
SS
+
0.003
+
0.17
V
CC
V
CC
V
CC
0.27
0.019
0.22
79
387
0.6
240
597
2.20
878
1491
V
0CHA
0 V battery charging 0.26
0.75
1.25
V
11
6
function “available”
0 V battery charging
0.20
0.88
1.57
V
12, 13
6
0 V battery charge inhibition battery voltage 1, 2 V
0INH1, 2
function
“unavailable”
*1.
Auxiliary overcharge detection voltage is equal to the overcharge detection voltage times 1.11 for the
products without overcharge hysteresis, and times 1.25 for other products.
*2.
Temperature coefficient 1 for detection voltage should be applied to overcharge detection voltage,
overcharge release voltage, overdischarge detection voltage, and overdischarge release voltage.
*3.
Temperature coefficient 2 for detection voltage should be applied to overcurrent detection voltage.
*4.
The DO pin and CO pin logic are established at the operating voltage.