BATTERY PROTECTION IC FOR SINGLE-CELL PACK
S-8261 Series
Table 1 (2 / 2)
Rev.1.9
_00
Overcharge
Overdischarge
Overcurrent 1
detection delay time
detection delay time
detection delay time
S-8261AAGMD-G2G-T2
1.2 s
144 ms
9 ms
S-8261AAHMD-G2H-T2
1.2 s
144 ms
9 ms
S-8261AAJBD-G2J-TF
1.2 s
144 ms
9 ms
S-8261AAJMD-G2J-T2
1.2 s
144 ms
9 ms
S-8261AALMD-G2L-T2
1.2 s
144 ms
9 ms
S-8261AAMMD-G2M-T2
1.2 s
144 ms
9 ms
S-8261AANMD-G2N-T2
1.2 s
144 ms
9 ms
S-8261AAOMD-G2O-T2
1.2 s
144 ms
9 ms
S-8261AAPMD-G2P-T2
1.2 s
144 ms
9 ms
S-8261AARBD-G2R-TF
1.2 s
144 ms
9 ms
S-8261AARMD-G2R-T2
1.2 s
144 ms
9 ms
S-8261AASMD-G2S-T2
1.2 s
144 ms
4.5 ms
S-8261AAUMD-G2U-T2
4.6 s
144 ms
9 ms
S-8261AAVBD-G2V-TF
4.6 s
144 ms
9 ms
S-8261AAXMD-G2X-T2
4.6 s
144 ms
9 ms
S-8261AAZMD-G2Z-T2
1.2 s
144 ms
9 ms
S-8261ABAMD-G3A-T2
4.6 s
144 ms
9 ms
S-8261ABBMD-G3B-T2
1.2 s
144 ms
9 ms
S-8261ABCMD-G3C-T2
1.2 s
144 ms
9 ms
S-8261ABDBD-G3D-TF
1.84 s
115 ms
7.2 ms
S-8261ABEBD-G3E-TF
1.2 s
144 ms
9 ms
S-8261ABGBD-G3G-TF
1.2 s
36 ms
9 ms
S-8261ABHBD-G3H-TF
0.3 s
36 ms
18 ms
S-8261ABIBD-G3I-TF
1.2 s
36 ms
9 ms
S-8261ABJMD-G3J-T2
1.2 s
144 ms
9 ms
S-8261ABKMD-G3K-T2
1.2 s
144 ms
9 ms
S-8261ABLBD-G3L-TF
1.2 s
36 ms
9 ms
S-8261ABMMD-G3M-T2
1.2 s
144 ms
9 ms
S-8261ABNMD-G3N-T2
1.2 s
144 ms
9 ms
S-8261ABOBD-G3O-TF
1.2 s
144 ms
9 ms
S-8261ABPMD-G3P-T2
1.2 s
144 ms
9 ms
S-8261ABRMD-G3R-T2
1.2 s
144 ms
9 ms
S-8261ABSMD-G3S-T2
1.2 s
144 ms
9 ms
Remark
It is possible to change the detection voltages of the product other than above. The delay times
can also be changed within the range listed bellow. For details, please contact SII marketing
department.
Model No.
Delay time
Symbol
Selection range
Remarks
Overcharge detection delay time
t
CU
0.15 s
1.2 s
4.6 s
Choose from the left.
Overdischarge detection delay time
t
DL
36 ms
144 ms 290 ms Choose from the left.
Overcurrent 1 detection delay time
t
lOV1
4.5 ms
9 ms
18 ms
Choose from the left.
Remark
The values surrounded by bold lines are the delay time of the standard products.
6
Seiko Instruments Inc.