Si8430/31/35
Table 1. Electrical Characteristics (Continued)
(V
DD1
= 5 V, V
DD2
= 5 V, T
A
= –40 to 125 ºC)
Parameter
For All Models
Output Rise Time
Output Fall Time
Common Mode Transient
Immunity
Enable to Data Valid
Enable to Data Tri-State
Start-up Time
2
Symbol
t
r
t
f
CTMI
t
en1
t
en2
t
SU
Test Condition
C
L
= 15 pF
See Figure 2
C
L
= 15 pF
See Figure 2
V
I
= V
DD
or 0 V
See Figure 1
See Figure 1
Min
—
—
25
—
—
—
Typ
2
2
30
5
5
3
Max
—
—
—
—
—
—
Unit
ns
ns
kV/µs
ns
ns
µs
Notes:
1.
t
PSK(P-P)
is the magnitude of the difference in propagation delay times measured between different units operating at the
same supply voltages, load, and ambient temperature.
2.
Start-up time is the time period from the application of power to valid data at the output.
ENABLE
OUTPUTS
t
en1
t
en2
Figure 1. ENABLE Timing Diagram
50%
Typical
Input
t
PLH
90%
50%
90%
10%
t
PHL
Typical
Output
10%
t
r
t
f
Figure 2. Propagation Delay Timing
6
Rev. 0.3