DATA SHEET • AV110-73, AV110-73LF
Operating Characteristics at 25 °C (V
S
= 3 V)
Parameter
(1)
Switching characteristics
Rise, on
Fall, off
Intermodulation intercept point (IIP3)
(2)
Thermal resistance
Control voltage (V
C
)
Supply voltage (V
S
)
Control current (I
C
)
Supply current (I
S
)
1. All measurements made in a 50
Ω
system, unless otherwise specified.
2. For worst-case state.
Condition
10/90% or 50% CTL to 90% RF
90/10% RF or 50% CTL to 10% RF
For two-tone input power +0 dBm
Frequency
Min.
Typ.
1.0
0.3
Max.
Unit
µs
µs
dBm
°C/W
1.9 GHz
0
3
12
25
V
S
0.2 x V
C
150
V
V
mA
µA
Typical Performance Data @ 1.9 GHz
(Unless Otherwise Specified)
0
-5
-10
2.0
1.9
1.8
1.7
1.6
Attenuation (dB)
-15
-20
-25
-30
-35
-40
0
0.5
1.0
1.5
2.0
2.5
3.0
VSWR
1.5
1.4
1.3
1.2
1.1
1.0
0
Input
Output
0.5
1.0
1.5
2.0
2.5
3.0
V
C
(V)
V
C
(V)
Attenuation vs. Control Voltage
@ 1900 MHz
0
-5
-10
VSWR vs. Control Voltage
Attenuation (dB)
-15
-20
-25
-30
-35
0
0.5
1.0
1.5
2.0
2.5
3.0
V
C
(V)
Attenuation vs. Control Voltage
@ 2400 MHz
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
2