DATA SHEET
PS196-315: Voltage Controlled Phase Shifter
1.5–3.0 GHz
Features
1500–3000 MHz frequency band
●
65–100-degree phase shift range
●
2 dB insertion loss variation
●
0–12 V control voltage range
●
Specified 33 dBm IP3 @ 1900 MHz
●
Small footprint LGA package
●
Lead (Pb)-free and RoHS-compliant
●
Connection Diagram
RF In/Out
V
CONTROL
10 pF
Control
Voltage
RF In/Out
V
CONTROL
Description
The PS196-315 is a voltage controlled phase shifter that employs
a monolithic quadrature hybrid and a pair of selected silicon
varactor diodes to achieve 100-degree phase shift and low
insertion loss. The PS196-315 is packaged in the small outline
LGA (Land Grid Array) surface mount package with the internal
elements affixed to an organic BT substrate.
10 pF
NEW
Skyworks offers lead (Pb)-free, RoHS (Restriction of
Hazardous Substances)-compliant packaging.
Electrical Specifications at 25 °C
Z
O
= 50
Ω,
unless otherwise noted
Parameter
Phase shift
Control voltage (V
CONTROL
) range
Control current
Insertion loss in BW
I.L. deviation in BW
Return loss in BW
IM3
IP3
P
IN
= 8 dBm, 1900/1905 MHz, V
CONTROL
= 0 V
Derived from IM3
33
V
CONTROL
= 12 V
V
CONTROL
= 0–12 V
V
CONTROL
= 0–12 V
1930–1990 MHz
1930–1990 MHz
1500–3000 MHz
Condition
At F
O
, V
CONTROL
= 12 V
Frequency
1930–1990 MHz
Min.
65
0
Typ.
85
Max.
100
12
1
3.3
2
-7
-50
Unit
Deg.
V
mA
dB
dB
dB
dBc
dBm
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
200241 Rev. A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • September 13, 2006