CINT1150
150W Single Output
Industrial Series
General Specifications
(continued)
Earth Leakage
Current
Efficiency
<750μA@264Vac, 60Hz, NC
Short Circuit
Protection
Overvoltage
Protection
Switching Frequency
Provided - no damage will occur if the output
is shorted. Hiccup Mode
OVP firing reduces output voltage to <50%
of nominal in <50mS. See chart for trip
range.
PFC: Variable 30-400kHz.
Main Converter: Variable 35-180kHz, 65-
70kHz at full load.
Input-Output: 4000Vac
Input-Ground: 1800Vac
Output-Ground: 500Vac
-10°C to +70°C
88% typical at 115Vac
150W continuous with 200 lfm airflow, 100W
convection cooled – See chart for specific
voltage model ratings.
50% load step.
i/t:
<0.2A/μS
Max Volt Deviation = 3%
Output Power
Transient
Response
Ripple and Noise
Isolation
Operating
Temperature
Temperature
Derating
Storage Temperature
See chart
Output Voltage
Voltage
Adjustability
Minimum Load
See chart
Derate output power linearly above 50°C to
50% at 70°C
+/-5% from nominal
-40°C to +85°C
Not required
Altitude
Operating: -500 to 10,000 ft
Non-operating: -500 to 40,000 ft.
Total Regulation
+/- 5%. See chart
Operating: 0.003g/Hz, 1.5grms overall, 3
axes, 10 min/axis
Non-Operating: 0.026g2/Hz, 5.0grms overall,
3 axes, 1 hr/axis
W: 2.0” x L: 4.0” x H: 1.3”
Relative Humidity
5% to 95%, non-condensing
Operating: Half-sine, 20gpk, 10ms, 3 axes, 6
shocks total
Non-Operating: Half-sine, 40 gpk, 10 ms, 3
axes, 6 shocks total
EN/CSA/UL/IEC60950-1, 2nd Edition
Vibration
Shock
Dimensions
Safety Standards
Weight
183g
MTBF
640,000 hours at 100W convection,
1,500,000 hours at 150W with 200LFM air
Auxiliary Signals
AC Power Fail:
During normal operations, stays HIGH.
Power Fail:
Goes LOW with 5 mS warning before loss
of output power due to AC failure
Open collector logic signal goes and stays HIGH
100mS to 500mS after main output reaches
regulation.
DC OK:
www.slpower.com
CINT1150 REV 2.6, 12-NOV-12
2