40W
O
PEN
-F
RAME
S
WITCHING
P
OWER
S
UPPLIES
Model
Output Current Output
Output Voltage Min. Nom. Max. Voltage Line Load Cross-
Output (V)
(A)
(A)
(A)
Tol. Reg. Reg. Reg.
Model
Output Current Output
Output Voltage Min. Nom. Max. Voltage Line Load Cross-
Output (V)
(A)
(A)
(A)
Tol. Reg. Reg. Reg.
DC-DC Duals
DC2-40-1AC
DC2-40-2AC
DC2-40-3AC
DC2-40-4AC
V1
V2
V1
V2
V1
V2
V1
V2
+5
+12
+5
+15
+5
+24
+5
+28
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
36-75 VDC Input
3.00 5.00 1.0%
2.00 3.00 5.0%
3.00 5.00 1.0%
1.70 2.00 5.0%
3.00 5.00 1.0%
1.00 1.50 5.0%
3.00 5.00 1.0%
1.00 1.00 5.0%
0.2% 1.0% —
0.5% 3.0% 4.0%
0.2% 1.0% —
0.2% 3.0% 4.0%
0.2% 1.0% —
0.2% 3.0% 4.0%
0.2% 1.0% —
0.5% 3.0% 4.0%
AC-DC Triples
MDU3-40-1AD
V1
V2
V3
V1
V2
V3
V1
V2
V3
V1
V2
V3
+5
+12
-12
+5
+12
-5
+5
+15
-15
+5
+24
-12
To UL544/EN60-601/CSA 22.2-601.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
3.00 5.00 1.0%
1.50 3.00* 5.0%
0.50 0.70 5.0%
3.00 5.00 1.0%
1.50 3.00* 5.0%
1.00 1.00 3.0%
3.00 5.00 1.0%
1.20 2.00
5.0%
0.50 0.60 5.0%
3.00 5.00 1.0%
0.75 1.50
§
5.0%
0.50 0.70 5.0%
0.2% 1.0% —
1.0% 3.0% 4.0%
0.2% 1.0% 1.0%
0.2% 1.0% —
1.0% 3.0% 4.0%
0.2% 1.0% 1.0%
0.2% 1.0% —
1.0% 3.0% 4.0%
0.2% 1.0% 1.0%
0.2% 1.0% —
1.0% 3.0% 4.0%
0.2% 1.0% 1.0%
MDU3-40-2AD
MDU3-40-3AD
AC-DC Triples
FLU3-40-1AD
V1
V2
V3
V1
V2
V3
V1
V2
V3
V1
V2
V3
+5
+12
-12
+5
+12
-5
+5
+15
-15
+5
+24
-12
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
85-265 VAC Input
3.00 5.00 1.0%
1.50 3.00* 5.0%
0.50 0.70 5.0%
3.00 5.00 1.0%
1.50 3.00* 5.0%
1.00 1.00 3.0%
3.00 5.00 1.0%
1.20 2.00
5.0%
0.50 0.60 5.0%
3.00 5.00 1.0%
0.75 1.50
§
5.0%
0.50 0.70 5.0%
5.00 6.00 1.0%
0.30 0.50 4.0%
0.30 0.50 4.0%
5.00 6.00 1.0%
0.30 0.50 4.0%
0.30 0.50 4.0%
0.2% 1.0% —
1.0% 3.0% 4.0%
0.2% 1.0% 1.0%
0.2% 1.0% —
1.0% 3.0% 4.0%
0.2% 1.0% 1.0%
0.2% 1.0% —
1.0% 3.0% 4.0%
0.2% 1.0% 1.0%
0.2% 1.0% —
1.0% 3.0% 4.0%
0.2% 1.0% 1.0%
0.2% 0.5% —
0.5% 1.0% 1.0%
0.5% 1.0% 1.0%
0.2% 0.5% —
0.5% 1.0% 1.0%
0.5% 1.0% 1.0%
MDU3-40-4AD
DC-DC Triples
DC3-40-1AC
V1
V2
V3
V1
V2
V3
V1
V2
V3
V1
V2
V3
+5
+12
-12
+5
+12
-5
+5
+15
-15
+5
+24
-12
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
36-75 VDC Input
3.00 5.00 1.0%
1.50 3.00* 5.0%
0.50 0.70 5.0%
3.00 5.00 1.0%
1.50 3.00* 5.0%
1.00 1.00 3.0%
3.00 5.00 1.0%
1.20 2.00
5.0%
0.50 0.60 5.0%
3.00 5.00 1.0%
0.75 1.50
§
5.0%
0.50 0.70 5.0%
0.2% 1.0% —
1.0% 3.0% 4.0%
0.2% 1.0% 1.0%
0.2% 1.0% —
1.0% 3.0% 4.0%
0.2% 1.0% 1.0%
0.2% 1.0% —
1.0% 3.0% 4.0%
0.2% 1.0% 1.0%
0.2% 1.0% —
1.0% 3.0% 4.0%
0.2% 1.0% 1.0%
FLU3-40-2AD
FLU3-40-3AD
DC3-40-2AC
FLU3-40-4AD
DC3-40-3AC
FLU3-40-5AD
V1 5
(ISO)
V2 12
(ISO)
V3 12
(ISO)
V1 5
(ISO)
V2 15
(ISO)
V3 15
(ISO)
DC3-40-4AC
FLU3-40-6AD
* Peak output current rating = 5.0A (<60 seconds, duty cycle <10%).
† Peak output current rating = 3.0A (<60 seconds, duty cycle <10%).
§ Peak output current rating = 2.0A (<60 seconds, duty cycle <10%).
Notes
1. Replace the input line fuse with the same type and rating.
Recommended: 2A/250V slow-blow fuse.
2. The sum of primary and auxiliary output currents from triple
output models -1AD through -4AD must not exceed 5.0A.
3. Hi-pot isolation is 2200 VDC from the input of the supply to
ground for 60 seconds.
4. All measurements are made directly at the terminals of the
power supply.
5. Peak-to-peak and RMS metering equipment must have a 20
MHz frequency response with probes and cables that main-
tain a frequency response of 20 Hz to 20 MHz. Output rip-
ple and spikes are measured directly at the output terminals
of the power supply with a 0.1 µF ceramic capacitor. The
probe ground band must make direct contact with the output
return or common terminal to prevent erroneous noise mea-
surements.
6. MTBF is calculated using the parts stress method in MIL-
HDBK 217F (ground benign, T
A
= +25°C).
7. Output voltage tolerance is measured under nominal load
current conditions.
8. Line regulation is measured under nominal load conditions
as the input voltage is varied from 85 to 265 VAC (ac-input
models) or from 36 to 75 VDC (dc-input models).
9. Load regulation is measured at 115 VAC or 230 VAC. For
single output models, load regulation is measured while out-
put current is varied from 0% to 100% of full load. With mul-
tiple output models, the output under test is brought to 60%
Model Selection Guide
FLU 2 - 40 - 1 A D
Series
FLU = AC Input
MDU = AC Input
(UL544/IEC601 Safety)
DC = DC Input
Number of Outputs
Output Power (W)
Input Voltage
D = 85-265 VAC
C = 36 to 75 VDC
Construction
A = Open PCB
B = L-Bracket
C = Full Enclosure
Output Voltage (Model)
10.
11.
12.
13.
14.
of nominal load; load current is then varied +40%/-30% of nominal while other outputs
are held at nominal load conditions.
Cross-regulation is tested by changing the load on the primary output from 50% to
100% of nominal load while measuring the voltage change on the auxiliary output
under test.
The FLU1-40, FLU2-40 and FLU3-40 series are approved to UL1950 (File E140439),
CSA22.2 No. 234 (File LR52335), EN60950/IEC950/DIN VDE 0805 (TÜV Licenses
R679206, R0097621, R9071501), and Austel CCL (Certificate A92/PS/004).
The FLU3-40 series has BABT/EN41003 approval ((NS/4199/123/R/604674).
The MDU1-40, MDU2-40 and MDU3-40 series are approved to UL544 (File E151357),
CSA 22.2 No. 601.1 (File LR52335) and EN60-601/IEC601-1/DIN VDE 0750 (TÜV
Licenses R9271474, R9271475, R9271476).
The DC2-40 and DC3-40 series are approved to UL1950 (File E140439), CSA22.2 No.
234 (File LR52335), and EN60950/IEC950/DIN VDE 0805 (TÜV License R9071501).
POWER GENERAL