GPFC160-5图片预览
型号: GPFC160-5
PDF下载: 下载PDF文件 查看货源
内容描述: 160瓦的全球绩效切换器 [160 Watt Global Performance Switchers]
分类和应用: 电源电路输出元件
文件页数/大小: 2 页 / 245 K
品牌: SLPOWER [ SL Power Electronics ]
 浏览型号GPFC160-5的Datasheet PDF文件第2页  
GPFC160 Commercial
160 Watt Global Performance Switchers
FEATURES:
3.0 watts/cu.in. power density
Compact size (4.5" x 7.0" x 1.7"; meets 1U height)
Power factor corrected to IEC 1000-3-2; Class A
Less than 300 µA leakage
EMI compliance to CISPR22, FCC Class B
Commercial Approved to UL1950, IEC950, EN60950
and CSA 22.2 No. 950
• 2-year warranty
marked to LVD
SPECIFICATIONS:
Ac Input
85-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current 2.3 A at 90 Vac, 60 Hz with full
rated load. Input current harmonic content meets the
requirements of IEC1000-3-2.
Hold-upTime
25 ms minimum from loss of ac input at full load, nominal
line (115 Vac).
Output Power
Total regulation is the maximum deviation from the
nominal voltage for all steady-state loading conditions.
Each individual output is to be used within its specified
limits of that output. Peak ratings are for 60 s maximum
duration, 10% duty cycle.
Overload Protection
Fully protected against short circuit and output overload.
Short circuit protection is cycling type power limit.
Recovery after fault is automatic.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential
mode. Measured with noise probe directly across output
terminals of the power supply.
Transient Response
500 ms typical response time for return to within 0.5% of
final value for a 50% load step change,
∆i/∆t<
0.2 A/ms.
Maximum voltage deviation is 3.5%.
Remote Sense
Provided as a standard feature. Capable of compensating
for 0.25 V total of cabling losses.
Overvoltage Protection
Built in on all models. OVP crowbar reduces output
voltage below nominal rating in less than 50 ms.
Voltage Adjustment
Main output ±5%.
Input Protection
Internal ac fuse provided on all models. Fuse does not
blow on overload or short circuit—fuse blows only if
catastrophic failure occurs in the unit.
Inrush Current
Inrush 240 Vac is less than 37 A, averaged over the first
ac half-cycle under cold start conditions. Limiting pro-
vided by internal thermistors.
Fan Output
An additional 12 Vdc, 250 mA output suitable for power-
ing a dc fan is included in all models. The output is
protected by an internal PTC in the event of an overload.
Thermal Shutdown
Provided as a standard feature. Designed to protect the
unit from prolonged over temperature.
Power Fail
TTL or CMOS compatible output goes low (<0.5 V) 8 ms
before output voltage drops more than 4% below nominal
voltage upon loss of ac power. The signal is factory set to
trip when input power can no longer sustain the output.
Temperature Coefficient
0.03%/°C typical on all outputs.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the
following emissions requirements:
EMI SPECIFICATIONS
Conducted Emissions
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
COMPLIANCE LEVEL
EN55022 Class B; FCC Class B
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.
Commercial Safety
Approved to UL1950, CSA22.2 950, IEC950, and
EN60950. UL file #E135803 commercial; CSA #LR46516.
The output(s) are intended for safety earthed Signal
Output and Intermediate Circuits only. All dc outputs are
SELV under normal and single fault conditions.
62
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com