SL POWER ELECTRONICS CORP.
6050 King Drive, Bdlg A
Ventura, CA 93003 + 805-486-4565
Internet:
www.slpower.com
GPM55 SERIES
INSTALLATION INSTRUCTIONS
RATINGS
Model
GP M 5 5 A
GP M 5 5 B
GP M 5 5 C
GP M 5 5 D
GP M 5 5 E
GP M 5 5 F
GP M 5 5 -5
GP M 5 5 -1 2
GP M 5 5 -1 5
GP M 5 5 -2 4
GP M 5 5 -2 8
Input: 100-240 VAC, 1.7 A, 50/60 Hz
Outputs: 55 Watts Maximum Continuous Power - Total of all Outputs.
Output #1
+5 VDC 6 A
+5 VDC 6 A
+5 VDC 6 A
+5 VDC 6 A
+5 VDC 6 A
+5 VDC 6 A
5 VDC 1 1 A
1 2 VDC 4 .7 A
1 5 VDC 3 .7 A
2 4 VDC 2 .3 A
2 8 VDC 2 .0 A
Isc
4A
4A
4A
4A
4A
4A
5A
2A
2A
1A
1A
Output #2
+1 2 VDC
+1 2 VDC
+1 5 VDC
+2 4 VDC
+2 4 VDC
+1 2 VDC
3A
3A
3A
1 .5 A
1 .5 A
3A
Isc
4A
4A
4A
2A
2A
2A
Output #3
+1 2 VDC 1 A
-5 VDC 1 A
-5 VDC 1 A
+1 2 VDC 1 A
+1 5 VDC 1 A
+1 5 VDC 1 A
Isc
3A
3A
3A
3A
3A
3A
Output #4
-1 2 VDC
-1 2 VDC
-1 5 VDC
-1 2 VDC
-1 5 VDC
-1 5 VDC
1A
1A
1A
1A
1A
1A
Isc
3A
3A
3A
3A
3A
3A
Notes:
1. Isc = Maximum output short circuit current.
2. Maximum ambient temperature for continuous output power of 55W is 50°C.
3. Maximum Relative Humidity 96%, no condensation.
SAFETY DECLARATION:
SL Power Electronics Corp. (SLPE) declares under our sole responsibility
that all models listed above are in conformity with the applicable requirements of EN60950-1 following the
provisions of the Low Voltage Directive 2006/95/EC. All models are Certified to be in compliance with the
applicable requirements of CSA 22.2 No. 234 (Level 3) (with additional tests to C22.2 No 601.1-M90 per
T.I.L. CA-08), EN/IEC/UL 60601-1.
CLASSIFICATION:
(In accordance with sub-
clause 5 of IEC 60601-1)
(5.1) Protection against electric shock = Class I
(5.2) Degree of protection against electric shock = Signal output or intermediate
(5.3) Protection against harmful ingress of water = Ordinary (no protection)
(5.5) Have not been evaluated for use in the presence of a flammable anaesthetic mixture with
air, oxygen, or nitrous oxide. This evaluation is made on the end equipment by the OEM.
(5.6) Mode of operation = Continuous
CAUTION:
When performing Dielectric Strength Tests, catastrophic failure of the unit may result if a Dielectric Strength
test voltage greater than 1800 Vac is applied between primary and secondary circuits. The components providing isolation
from primary to secondary cannot be tested while installed in the power supply without overstressing basic (primary to
ground) insulation. All isolating components are individually 100% tested at 4800 Vac prior to installation.
ISOLATION:
The creepage distance between primary and ground is 4 mm minimum; between primary and secondary
circuits is 8 mm minimum. Secondary to ground creepage is not defined or controlled. The output common is bypassed to
ground using a 0.01µF 1KV capacitor. The required creepage and clearance distances from primary circuits to ground and
secondary circuits must be maintained after installation to preserve the intended safety.
GROUNDING:
The Protective Earth (ground) terminal J1, pin 1 and all of the pads around the mounting holes must be
bonded to Protective Earth in the host equipment. Metallic spacers should be used to mount supply to metal surfaces. When
mounting to non-metallic surfaces, connect all mounting pads together and bond to earth. Using the Protective Earth terminal
on the supply for grounding the host equipment is not recommended. A separate dedicated grounding point should be used.
OUTPUTS:
All output commons should be connected to Protective Earth in the end application. The output(s) are intended
for Protectively Earthed Signal Output and Intermediate Circuits only. The output(s) are not acceptable for patient connection
without additional isolation. All DC outputs are SELV under normal and single fault conditions.
41-32494-0001 REV. L