欢迎访问ic37.com |
会员登录 免费注册
发布采购

MAX-504-1205 参数 Datasheet PDF下载

MAX-504-1205图片预览
型号: MAX-504-1205
PDF下载: 下载PDF文件 查看货源
内容描述: 400 , 500 WATTS多输出 [400, 500 WATTS MULTIPLE OUTPUT]
分类和应用: 输出元件
文件页数/大小: 2 页 / 97 K
品牌: SLPOWER [ SL Power Electronics ]
 浏览型号MAX-504-1205的Datasheet PDF文件第1页  
4 0 0 , 5 0 0 WATTS  
1 1 .5 ” x 5 ” x 2 .5 ”  
MAX-4 0 0 , 5 0 0 MTC-5 0 0  
MAX, MTC-500  
MAX, MTC-500 with Option F  
4.5 lbs - 2.0 kgs  
5.2 lbs - 2.4 kgs  
Dimensions:  
Inches  
Millimeters  
SPECIFICATIONS: ALL MODELS  
INPUT  
AC Input: 90-132 Vac/180-264 Vac, 47 to 63 Hz. User selectable. See option “Afor automatic  
line selection. Internally fused for 12 A.  
Inrush: Cold start AC current is less than 80 A at 115 Vac and 20 A at 230 Vac. Limited by  
thermistor.  
Holdup Time: 16 ms minimum after removal of power, at nominal line, full load.  
Efficiency: 80% typical.  
Option “G, DC Power Good: Provides a TTL “1” open collector when output #1 is above 4.6  
V nominal. Not available if option “P” is selected.  
Option “P”, AC Power Fail: Provides TTL 0” 5 ms before output voltage goes out of  
regulation band upon loss of AC power. VMEbus compatible, provides 48 mA sink current  
capability. Not available if option “G” is selected.  
Option “V, Fan/Cover Assembly: Low profile, end venting cover with integral ball-bearing  
fan.  
Brownout Protection: Holds regulation to 85 Vac or 170 Vac.  
OUTPUT  
Consult factory for other available options.  
Adjustability: User adjustable ±5% minimum.  
Line & Load Reg: ±1% over AC input range and 0 to 100% load change. Output #1 requires  
minimum load of 10%.  
Ripple & Noise: Less than 1% p-p or 100 mV, whichever is greater.  
Remote Sense (Output #1): Compensates for 250 mV total line drop. Open sense lead  
protection.  
AC INPUT  
FUNCTION  
115 VAC  
230 VAC  
CONNECTORS  
Input Select  
Short  
Line  
Open  
0.250 Male Fastons  
TB1- (L)  
TB1- (N)  
Line 1  
Line 2  
Barrier strip  
#6-32 screws  
3/8 centers.  
Temperature Coefficient: 0.02% per degree C.  
Neutral  
Stability: 0.1% over 8 hours after 30 minutes warm-up.  
Transient Response (Output #1): Output voltage returns to within 1% in less than 500 µs for  
a 50% load change. Peak transient does not exceed 5%.  
Overload Protection: All outputs are protected against overload and short circuit. Automatic  
recovery upon removal of fault.  
TB1- (  
)
Safety Ground  
Safety Ground  
DC OUTPUT  
FUNCTION  
LOCATION  
NOTES  
CONNECTOR  
Overvoltage Protection (Output #1): Protects load against power supply induced overvoltage.  
Trip point is factory set so that output voltage cannot exceed 136% of nominal.  
Remote Inhibit: Contact closure to the negative sense line drops output power to nominal  
zero.  
Output #1  
Terminal marked +V Main Output  
Terminal marked COM Rtn (Common)  
TB2-3  
Bus bars  
#1/4-20 screws  
Output #2  
Output #3  
TB2-4  
TB2-5  
TB2-4  
TB2-1  
TB2-2  
Rtn (Common)  
Reverse Voltage: Protected against reverse voltage up to supply current rating.  
Barrier Strip  
#6-32 screws  
3.8” centers  
ENVIRONMENTAL  
Rtn (Common)  
Thermal Protection: Shuts down power supply if overheated. Automatic recovery.  
Temperature Range: 0° to 50°C at full ratings. Derate to half power at 70°C.  
Safety Agencies: Most models are approved to UL1950; CSA 22.2 #234; IEC 950 and TÜV  
EN60950, Class 1 SELV., CE 72/23/EEC/93/68EEC (low voltage directive).  
Conducted RFI: Meets FCC Part 15, Subpart J, Class A; EN55022 Class B; CISPR 22 Class B.  
Cooling: 30 CFM required to achieve full ratings.  
Output #4*  
(+)  
(–)  
(If provided)  
*Rtn connected to common only if output is polarized in product selection chart  
STATUS AND CONTROL  
Output Isolation: Isolated from ground 50 Vdc.  
FUNCTION  
LOCATION  
NOTES  
CONNECTOR  
Remote Sense  
J1-1 (+S)  
Output #1 Sense  
Output #1 Sense Rtn  
Reference to J1-2  
AMP MTA type  
#640456-4 pin  
header (locking)  
OPTIONS:  
J1-2 (-S)  
J1-3 (PF)  
Option “A, AC Auto-Range: Automatically selects proper AC line voltage range to enable  
power operation at either 115 or 230 Vac without user intervention.  
Option “C, Cover: Limits contact with power supply interior.  
Option “F”, Fan/Cover Assembly: Cover with integral ball-bearing fan provides proper cooling  
to achieve full ratings at 50°C ambient temperature.  
AC Power Fail or  
DC Power Good*  
Inhibit  
J1-4(1H)  
Short to J1-2  
*Optional function  
Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com