欢迎访问ic37.com |
会员登录 免费注册
发布采购

MDU1-40-2AD 参数 Datasheet PDF下载

MDU1-40-2AD图片预览
型号: MDU1-40-2AD
PDF下载: 下载PDF文件 查看货源
内容描述: 开架式开关电源 [OPEN-FRAME SWITCHING POWER SUPPLIES]
分类和应用: 开关
文件页数/大小: 4 页 / 469 K
品牌: SLPOWER [ SL Power Electronics ]
 浏览型号MDU1-40-2AD的Datasheet PDF文件第2页浏览型号MDU1-40-2AD的Datasheet PDF文件第3页浏览型号MDU1-40-2AD的Datasheet PDF文件第4页  
40W
O
PEN
-F
RAME
S
WITCHING
P
OWER
S
UPPLIES
Single, Dual and Triple Output Models
Universal AC-Input and DC-Input Models
CE
Mark: UL/CSA/EN60950 Approvals
BABT Approvals
Austel CCL Certification
Models with UL544/CSA C22.2-601/EN60-601
Medical Safety Approvals
EN55022/FCC Class B Input Line Filter
0% Minimum Load Requirement
Over-Current/Short-Circuit Protection
2-Year Warranty
Minimum 200,000-Hour MTBF
C
HARACTERISTICS
Input Voltage .............................FLU and MDU models, universal
input range 85-265 VAC single
phase or 100-370 VDC. DC-input
models, 36-75 VDC (48V, nominal).
Input Line Frequency ................47-440 Hz (ac input models).
Input Line Protection .................MOV transient protected (FLU and
MDU series). Input line fuse provid-
ed on-board. (See Note 1.)
EMI Filter...................................Standard. Performance surpasses
conducted EMI requirements of
EN55022/FCC Class B by 10 dB, typ.
DC Output .................................See table. (Note 2.)
Continuous Output Power.........40W, maximum.
Leakage Current .......................MDU Series, non-patient contact rat-
ing: 500 µA, maximum.
Output Voltage Adjust ...............Primary output adjustable ±5%.
Auxiliary outputs fixed.
Efficiency...................................62-75%, typical (nominal input line
voltage, nominal load conditions).
Hold-Up Time ............................FLU and MDU models: 16 ms (115
VAC input), 32 ms (230 VAC input),
minimum, at full load
Overload Protection ..................Power-limit circuit.
Short-Circuit Protection.............Continuous.
Over-Voltage Protection............Primary output only.
Soft Start ...................................Standard on all models.
Design Topology .......................Flyback converter with current-mode
control.
Frequency of Operation ............40 kHz (fixed).
Hi-Pot Isolation..........................FLU Series: 5300 VDC, input-to-out-
put for one minute. (Note 3.)
MDU Series: 5700 VDC, input-to-out-
put for one minute. (Note 3.)
Noise, Ripple and Spike ...........1% peak-to-peak, maximum. (See
Note 5.)
Temperature Range ..................-20°C to +70°C.
Output Power De-Rating...........De-rate output power and current
linearly 2%/°C from +50°C to +70°C.
Temperature Coefficient ............±0.05%/°C over the entire operating
temperature range.
Relative Humidity ......................0 to 95%, non-condensing.
Altitude ......................................0 to 10,000 feet.
Cooling ......................................Convection cooling is adequate.
Moving air is recommended for oper-
ation in a confined area.
Storage Temperature ................-40°C to +85°C.
Storage Humidity ......................0 to 95%, non-condensing.
Mean Time Between Failures ...>200,000 hours. (Note 6.)
Model
Output Current Output
Output Voltage Min. Nom. Max. Voltage Line Load Cross-
Output (V)
(A)
(A)
(A)
Tol. Reg. Reg. Reg.
AC-DC Singles
FLU1-40-1AD
FLU1-40-2AD
FLU1-40-3AD
FLU1-40-4AD
FLU1-40-5AD
FLU1-40-6AD
V1
V1
V1
V1
V1
V1
5
9
12
15
24
28
0.0
0.0
0.0
0.0
0.0
0.0
85-265 VAC Input
8.00 8.00 1.0%
4.40 4.40 1.0%
3.30 3.30 1.0%
2.70 2.70 1.0%
1.70 1.70 1.0%
1.40 1.40 1.0%
0.1% 0.2%
0.1% 0.2%
0.1% 0.2%
0.1% 0.2%
0.1% 0.2%
0.1% 0.2%
AC-DC Singles
MDU1-40-1AD
MDU1-40-2AD
MDU1-40-3AD
MDU1-40-4AD
MDU1-40-5AD
MDU1-40-6AD
V1
V1
V1
V1
V1
V1
5
9
12
15
24
28
To UL544/EN60-601/CSA 22.2-601.1
0.0
0.0
0.0
0.0
0.0
0.0
8.00 8.00 1.0%
4.40 4.40 1.0%
3.30 3.30 1.0%
2.70 2.70 1.0%
1.70 1.70 1.0%
1.40 1.40 1.0%
0.1% 0.2%
0.1% 0.2%
0.1% 0.2%
0.1% 0.2%
0.1% 0.2%
0.1% 0.2%
AC-DC Duals
FLU2-40-1AD
FLU2-40-2AD
FLU2-40-3AD
FLU2-40-4AD
FLU2-40-5AD
FLU2-40-6AD
FLU2-40-7AD
V1
V2
V1
V2
V1
V2
V1
V2
V1
V2
+5
+12
+5
+15
+5
+24
+5
+28
5
(ISO)
5
(ISO)
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
85-265 VAC Input
3.00 5.00 1.0%
2.00 3.00 5.0%
3.00 5.00 1.0%
1.70 2.00 5.0%
3.00 5.00 1.0%
1.00 1.50 5.0%
3.00 5.00 1.0%
1.00 1.00 5.0%
6.00 6.00 1.0%
2.00 2.00 3.0%
2.00 3.00 1.0%
1.00 2.00 3.0%
1.50 2.50 1.0%
1.20 2.00 3.0%
0.2% 1.0% —
0.5% 3.0% 4.0%
0.2% 1.0% —
0.5% 3.0% 4.0%
0.2% 1.0% —
0.5% 3.0% 4.0%
0.2% 1.0% —
0.5% 3.0% 4.0%
0.2% 1.0% —
0.5% 1.0% 1.0%
0.2% 1.0% —
0.5% 1.0% 1.0%
0.2% 1.0% —
0.5% 1.0% 1.0%
V1 12
(ISO)
V2 12
(ISO)
V1 15
(ISO)
V2 15
(ISO)
AC-DC Duals
MDU2-40-1AD
MDU2-40-2AD
MDU2-40-3AD
MDU2-40-4AD
V1
V2
V1
V2
V1
V2
V1
V2
+5
+12
+5
+15
+5
+24
+5
+28
To UL544/EN60-601/CSA 22.2-601.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
3.00 5.00 1.0%
2.00 3.00 5.0%
3.00 5.00 1.0%
1.70 2.00 5.0%
3.00 5.00 1.0%
1.00 1.50 5.0%
3.00 5.00 1.0%
1.00 1.00 5.0%
0.2% 1.0% —
0.5% 3.0% 4.0%
0.2% 1.0% —
0.2% 3.0% 4.0%
0.2% 1.0% —
0.2% 3.0% 4.0%
0.2% 1.0%
0.5% 3.0%
4.0
08
POWER GENERAL
152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com