欢迎访问ic37.com |
会员登录 免费注册
发布采购

PBO-200 参数 Datasheet PDF下载

PBO-200图片预览
型号: PBO-200
PDF下载: 下载PDF文件 查看货源
内容描述: 200瓦的功率因数校正的宽范围可调多产出 [200 WATTS POWER FACTOR CORRECTED WIDE RANGE ADJUSTABLE MULTIPLE OUTPUTS]
分类和应用: 功率因数校正输出元件
文件页数/大小: 2 页 / 88 K
品牌: SLPOWER [ SL Power Electronics ]
 浏览型号PBO-200的Datasheet PDF文件第1页  
200 WATTS
9”x 5”x 2”
PBO-200
PBO-200
2.7 lbs - 1.4 kgs
Dimensions:
Inches
Millimeters
SPECIFICATIONS: ALL MODELS
INPUT
AC Input:
85-264 V AC continuous range, 47 to 65 Hz. Internally fused at 6.3 A.
Power Factor:
0.99 typical at full load. Meets EN61000-3-2.
Inrush:
Cold start AC current is less than 35 A at 115 Vac and 70 A at 230 Vac. Limited by a
thermistor.
Brownout Protection:
Holds regulation to 85 Vac.
Holdup Time:
20 ms after removal of power at nominal line and full load.
Efficiency:
75% typical.
AC Power Fail:
Provides TTL “0” 6 ms before output voltage goes out of regulation band
upon loss of ac power. Also provides a TTL level “0” for 100 ms (minimum) at starting.
OUTPUT
Adjustability:
Output #1 is adjustable ±5%. Output #3 and 4 are wide range adjustable,
(see table).
Line & Load Reg:
±0.6% on all outputs over AC input range and loads within the ranges
specified in the table.
Ripple & Noise:
Less than 1% p-p or 100 mV, whichever is greater.
Remote Sense
(Output #1): Compensates for 250 mV total line drop. Open sense lead
protection.
Temperature Coefficient:
To be determined.
Stability:
0.1% over 8 hours after 30 minutes warm-up.
Transient Response:
Output voltage returns to within 1% in less than 500 µs for a 25% load
change. Peak transient does not exceed 3%.
Overload Protection:
All outputs are protected against overload and Input Cycling off/on is
required to reset latched-off protection mode.
Overvoltage Protection
(Output #1): Protects load against power supply induced
overvoltage. Trip point is factory set so that output voltage cannot exceed 6.5 V.
Peak Output Current:
(Outputs #2 and 3) Dual current ratings define continuous and peak
currents. The peak current shown can be delivered for a maximum period of 15 seconds.
Remote Inhibit:
Contact closure to the negative sense line or a TTL level “0” turns off DC
outputs.
DC Power Good:
Provides a TTL “1” open collector when output #1 is above 4.6 V nominal.
Redundancy:
External OR-ing diodes and forced current sharing on output #1 provide “N+1”
capability. Remote sense (+S) compensates for additional 0.6 V diode voltage drop. When
the current sharing terminal is connected between units, current sharing remains within
10% of the unit’s full output current rating.
Reverse Voltage:
Protected against reverse voltage up to supply current rating.
Cooling:
30 CFM required to achieve full ratings.
Enable:
Contact closure in the negative output #1 terminal or a TTL level “0”, turns off DC
outputs.
ENVIRONMENTAL
Thermal Protection:
Shuts down power supply if overheated. Automatic recovery.
Temperature Range:
0° to 40°C at full ratings.Output power linearly derated to 50% at 70°C.
Safety Agencies:
UL1950; CSA 22.2 #950; VDE 0805 / EN 60950 CE markings to low voltage
directive – All pending.
Conducted RFI:
Meets FCC Part 151 Class B. EN 55022/B.
Output Isolation:
Isolated from ground 50 Vdc.
Cooling:
30 CFM required to achieve full ratings.
OPTIONS:
Option CF:
Available with enclosed cover and fan.
Consult factory for other available options.
AC INPUT (90-264 VAC Continuous Range)
FUNCTION
TB1- (L )
TB1- (N)
TB1- ( )
115 VAC
Line
Neutral
Safety Ground
230 VAC
Line 1
Line 2
Safety Ground
CONNECTOR
Barrier strip
#6-32 screws
0.375 inch centers
DC OUTPUT
FUNCTION
Output #1
Output #2
Output #3
Output #4
LOCATION
TB2-1
TB2-2
TB3-1
TB3-2
TB3-3
TB3-4
TB3-5
TB3-6
NOTES
4.75V to 5.25V
Rtn (Isolated)
11.5V to 25.2V
Rtn (Isolated)
9.5V to 15.8V
Rtn (Isolated)
4.75V to 12.6V
Rtn (Isolated)
CONNECTOR
Bus Bars
# 8 - 32 Screws
Barrier strip
#6-32 screws
0.325 inch centers
STATUS AND CONTROL
FUNCTION
Enable
DC Power Good
LOCATION
J1-1
J1-2
J1-4
J1-3
J2-2
J2-1
STATUS
Enable
Output #1 Rtn
DC Power Good
Output #1 Rtn
Output #1 Sense +
Output #1 Sense -
CONNECTOR
Molex part #
22 - 23 - 2041
mates with Molex
part # 22 - 01 - 3047
Molex part #
22 - 23 - 2021
mates with Molex
part # 22 - 01 - 3027
Remote Sense
Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com