PENT1040B
High Power PoE Gigabit Injector
Output
Voltage
56 V
Universal 40 Watt (Pre-IEEE802.3at Compliant)
For the most current data and application support visit www.slpower.com
Output Currents
Min
0.00 A
Ault Part Number
PENT1040B5600F01
Max
0.71 A
Max
Watts
40 W
Ripple
Vp-p max.
560 mV
Ault Part Number Key
1
Number of
Outputs
040
Output
Wattage
B
Configuration
Type
56
Output
Voltage
00
Output
Connector
F
Input
Configuration
01
Standard
(no modifications
or special packaging)
PENT
Product
Family
Name
Input Configuration
Pin Connections
United
Kingdom
(G)
Australian
IEC320
Shaver
C8
(E)
w/ground
C14
(N)
(F)
IEC320
w/o ground
C18
(Q)
N. America/
Japan
(B)
Europe
(M)
United
Kingdom
(G)
Australian
(E)
Shaver
C8
(N)
General Specifications (continued from p. 1)
Weight
(excluding cord)
7 Ounces, 200 Grams
5.24L x 2.13W x 1.42H (in)
133.0L x 54.0W x 36.0H (mm)
Black 94V0
Polycarbonate
Dual RJ45 jacks built into
the enclosure
Case and Dimension
Case Material
87654321
87654321
J2
(Power and Data Out)
(Rear of Unit)
J1
(Data In)
Cord and Connectors
PoE Gigabit Pin-out Connections:
POWER (+)
Data
Pins 4/5 (Data + PWR)
Data
Data
Data
Note:
POWER (-)
Personalized PoE
Options (additional costs may apply):
• Custom label artwork
• Custom agency approvals available
• Surge protection (Input & Output)
• Mounting bracket
• Custom PoE modifications
Pins 1/2 (Data Only)
Pins 3/6 (Data Only)
Pins 7/8 (Data + PWR)
= Transformer
LED Functions:
Amber
Green
Blink
Power On
Power Active
Load Error
Power over Ethernet Plus (known as PoEP and/or PoE+) IEEE802.3at:
• Proposed standard is in development; decision expected in the next
4-6 months
• Operates on Cat5 and higher infrastructure
• Uses all four pairs of standard Ethernet Category 5 cable to provide
up to 56 watts of power
• Backwards compatible with IEEE802.3af standard
SL Power Electronics Corp
•
6050 King Drive
•
Ventura, CA 93003
•
Phone:805.486.4565
•
Fax:805.487.8911
•
Email:info@slpower.com
•
www.slpower.com
Data Sheet © 2008 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
Rev.9/3/08