RPM-Based Fan Controller with HW Thermal Shutdown  
Datasheet  
Table 6.1 EMC2103 Register Set (continued)  
REGISTER  
NAME  
DEFAULT  
VALUE  
ADDR  
R/W  
FUNCTION  
LOCK  
PAGE  
69h  
R/W  
LUT Temp 4  
Setting 5  
Stores the threshold level for the  
Internal Diode channel (or Pushed  
Temp 2 temp) that is associated with  
the Drive 5 value  
7Fh  
(127°C)  
LUT  
Lock  
Page 64  
6Ah  
6Bh  
R/W  
R/W  
LUT Drive 6  
Stores the sixth programmed drive  
setting for the LUT  
92h  
LUT  
Lock  
Page 64  
Page 64  
LUT Temp 1  
Setting 6  
Stores the threshold level for the  
External Diode 1 channel that is  
associated with the Drive 6 value  
7Fh  
(127°C)  
LUT  
Lock  
6Ch  
6Dh  
R/W  
R/W  
LUT Temp 2  
Setting 6  
Stores the threshold level for the  
External Diode 2 channel that is  
associated with the Drive 6 value  
7Fh  
(127°C)  
LUT  
Lock  
Page 64  
Page 64  
LUT Temp 3  
Setting 6  
Stores the threshold level for the  
External Diode 3 channel (or Pushed  
Temp 1 temp) that is associated with  
the Drive 6 value  
7Fh  
(127°C)  
LUT  
Lock  
6Eh  
R/W  
LUT Temp 4  
Setting 6  
Stores the threshold level for the  
Internal Diode channel (or Pushed  
Temp 2 temp) that is associated with  
the Drive 6 value  
7Fh  
(127°C)  
LUT  
Lock  
Page 64  
6Fh  
70h  
R/W  
R/W  
LUT Drive 7  
Stores the seventh programmed drive  
setting for the LUT  
92h  
LUT  
Lock  
Page 64  
Page 64  
LUT Temp 1  
Setting 7  
Stores the threshold level for the  
External Diode 1 channel that is  
associated with the Drive 7 value  
7Fh  
(127°C)  
LUT  
Lock  
71h  
72h  
R/W  
R/W  
LUT Temp 2  
Setting 7  
Stores the threshold level for the  
External Diode 2 channel that is  
associated with the Drive 7 value  
7Fh  
(127°C)  
LUT  
Lock  
Page 64  
Page 64  
LUT Temp 3  
Setting 7  
Stores the threshold level for the  
External Diode 3 channel (or Pushed  
Temp 1 temp) that is associated with  
the Drive 7 value  
7Fh  
(127°C)  
LUT  
Lock  
73h  
R/W  
LUT Temp 4  
Setting 7  
Stores the threshold level for the  
Internal Diode channel (or Pushed  
Temp 2 temp) that is associated with  
the Drive 7 value  
7Fh  
(127°C)  
LUT  
Lock  
Page 64  
74h  
75h  
R/W  
R/W  
LUT Drive 8  
Stores the highest programmed drive  
setting for the LUT  
92h  
LUT  
Lock  
Page 64  
Page 64  
LUT Temp 1  
Setting 8  
Stores the threshold level for the  
External Diode 1 channel that is  
associated with the Drive 8 value  
7Fh  
(127°C)  
LUT  
Lock  
76h  
77h  
R/W  
R/W  
LUT Temp 2  
Setting 8  
Stores the threshold level for the  
External Diode 2 channel that is  
associated with the Drive 8 value  
7Fh  
(127°C)  
LUT  
Lock  
Page 64  
Page 64  
LUT Temp 3  
Setting 8  
Stores the threshold level for the  
External Diode 3 channel (or Pushed  
Temp 1 temp) that is associated with  
the Drive 8 value  
7Fh  
(127°C)  
LUT  
Lock  
Revision 0.85 (01-29-08)  
SMSC EMC2103  
DATA4S0HEET