Small Form Factor Three Port 10/100 Managed Ethernet Switch with Single MII/RMII/Turbo MII  
Datasheet  
CSR Read Auto  
CSR Read  
Increment /  
Decrement  
Idle  
Idle  
Write  
Write  
Command  
Register  
Command  
Register  
CSR_BUSY = 1  
CSR_BUSY = 1  
Read  
Read  
Command  
Register  
Command  
Register  
CSR_BUSY = 0  
CSR_BUSY = 0  
last  
data?  
Read Data  
Register  
No  
Read Data  
Register  
Yes  
Write  
Command  
Register  
Read Data  
Register  
Figure 6.2 Switch Fabric CSR Read Access Flow Diagram  
6.2.3  
Flow Control Enable Logic  
Each Switch Fabric port (0,1,2) is provided with two flow control enable inputs per port, one for  
transmission and one for reception. Flow control on transmission allows the transmitter to generate  
back pressure in half-duplex mode, and pause packets in full-duplex. Flow control in reception enables  
the reception of pause packets to pause transmissions.  
The state of these enables is based on the state of the port’s duplex and Auto-negotiation settings and  
the values of the corresponding Manual Flow Control register (Port 1 Manual Flow Control Register  
(MANUAL_FC_1), Port 2 Manual Flow Control Register (MANUAL_FC_2), or Port 0 Manual Flow  
Control Register (MANUAL_FC_0)). Table 6.1 details the Switch Fabric flow control enable logic.  
When in half-duplex mode, the transmit flow control (back pressure) enable is determined directly by  
the BP_EN_x bit of the port’s manual flow control register. When Auto-negotiation is disabled, or the  
MANUAL_FC_x bit of the port’s manual flow control register is set, the switch port flow control enables  
during full-duplex are determined by the TX_FC_x and RX_FC_x bits of the port’s manual flow control  
register. When Auto-negotiation is enabled and the MANUAL_FC_x bit is cleared, the switch port flow  
control enables during full-duplex are determined by Auto-negotiation.  
Revision 1.3 (08-27-09)  
SMSC LAN9303/LAN9303i  
DATA6S2HEET