CXA2016S
Sync Identification for CRT Display
Description
The CXA2016S is used for sync signal
identification and waveform shaping in the CRT
computers display for multi-scan system. There are
three types of sync input signals for identification:
separate sync, composite sync, and sync on video
signals.
Features
•
Power save function available (5 V power supply)
•
Clamp pulse output position selectable among sync
interval, back porch interval, and AUTO.
•
Polarity information of sync signals is output.
•
Polarity and amplitude of input signals:
Polarity
V. separate sync: Positive/Negative
Amplitude (Vp-p)
1 to 5
Operating Conditions
Supply voltage
22 pin SDIP (Plastic)
Absolute Maximum Ratings
(Ta=25°C)
•
Supply voltage
•
Operating temperature
•
Storage temperature
V
CC
12
V
°C
°C
mW
Topr –20 to +75
Tstg –65 to +150
P
D
962
•
Allowable power dissipation
H. separate sync: Positive/Negative
1 to 5
Composite sync: Positive/Negative
1 to 5
Sync on video:
Sync signals part of Negative
0.2 to 0.4
Video part
0 to 1.4
Applications
CRT display monitor
Pin Configuration (Top View)
1
2
3
V
CC
22
VD 21
V
SS
IN 20
V
SS
OUT 19
PH
16
VS IN
PV
V
CC
5 ± 0.25
V
Block Diagram
PVC
EVC
VS IN
PVC
EVC
2
3
1
17
Polarity
Check
V. Ramp
Generator
Exist
Check
21 VD
8
HD SEL
4
CS IN
5
6
7
8
PHC
EHC
Video IN
HD SEL
HD 18
CS IN
4
5
6
7
Polarity
Check
Exist
Check
18 HD
Logic
PV 17
PHC
9
ISC
Clamp
Pulse
Generator
Sync
Sep
Sync
Check
Bias
13 CLP OUT
14 CLP OUT
PH 16
EHC
CLP SEL 15
Video IN
15 CLP SEL
9
ISC
10 ISJ
11 GND
CLP OUT 14
CLP OUT 13
V
SS
REF 12
Level
Control
10
ISJ
19
V
SS
OUT
20
12
11
GND
22
V
CC
V
SS
IN V
SS
REF
Sony reserves the right to change products and specifications without prior notice. This information does not convey any license by
any implication or otherwise under any patents or other right. Application circuits shown, if any, are typical examples illustrating the
operation of the devices. Sony cannot assume responsibility for any problems arising out of the use of these circuits.
—1—
E95422B78-TE