欢迎访问ic37.com |
会员登录 免费注册
发布采购

ICX204AK 参数 Datasheet PDF下载

ICX204AK图片预览
型号: ICX204AK
PDF下载: 下载PDF文件 查看货源
内容描述: 对角线6毫米(类型1/3)与正方形像素的彩色摄像机逐行扫描CCD图像传感器 [Diagonal 6mm (Type 1/3) Progressive Scan CCD Image Sensor with Square Pixel for Color Cameras]
分类和应用: 传感器图像传感器摄像机
文件页数/大小: 23 页 / 281 K
品牌: SONY [ SONY CORPORATION ]
 浏览型号ICX204AK的Datasheet PDF文件第8页浏览型号ICX204AK的Datasheet PDF文件第9页浏览型号ICX204AK的Datasheet PDF文件第10页浏览型号ICX204AK的Datasheet PDF文件第11页浏览型号ICX204AK的Datasheet PDF文件第13页浏览型号ICX204AK的Datasheet PDF文件第14页浏览型号ICX204AK的Datasheet PDF文件第15页浏览型号ICX204AK的Datasheet PDF文件第16页  
ICX204AK  
Measurement conditions  
1) In the following measurements, the device drive conditions are at the typical values of the progressive scan  
mode, bias and clock voltage conditions.  
2) In the following measurements, spot blemishes are excluded and, unless otherwise specified, the optical  
black level (OB) is used as the reference for the signal output, which is taken as the value of the Gr/Gb  
signal output or the R/B signal output of the measurement system.  
Definition of standard imaging conditions  
1) Standard imaging condition I:  
Use a pattern box (luminance: 706cd/m2, color temperature of 3200K halogen source) as a subject. (Pattern  
for evaluation is not applicable.) Use a testing standard lens with CM500S (t = 1.0mm) as an IR cut filter  
and image at F5.6. The luminous intensity to the sensor receiving surface at this point is defined as the  
standard sensitivity testing luminous intensity.  
2) Standard imaging condition II:  
Image a light source (color temperature of 3200K) with a uniformity of brightness within 2% at all angles.  
Use a testing standard lens with CM500S (t = 1.0mm) as an IR cut filter. The luminous intensity is adjusted  
to the value indicated in each testing item by the lens diaphragm.  
3) Standard imaging condition III:  
Image a light source (color temperature of 3200K) with a uniformity of brightness within 2% at all angles.  
Use a testing standard lens (exit pupil distance –33mm) with CM500S (t = 1.0mm) as an IR cut filter. The  
luminous intensity is adjusted to the value indicated in each testing item by the lens diaphragm.  
1. G sensitivity, sensitivity comparison  
Set to standard imaging condition I. After selecting the electronic shutter mode with a shutter speed of  
1/100s, measure the signal outputs (VGr, VGb, VR and VB) at the center of each Gr, Gb, R and B channel  
screen, and substitute the values into the following formulas.  
VG = (VGr + VGb)/2  
Sg = VG × 100/30 [mV]  
Rr = VR/VG  
Rb = VB/VG  
2. Saturation signal  
Set to standard imaging condition II. After adjusting the luminous intensity to 20 times the intensity with the  
average value of the Gr signal output, 150mV, measure the minimum values of the Gr, Gb, R and B signal  
outputs.  
3. Smear  
Set to standard imaging condition II. With the lens diaphragm at F5.6 to F8, first adjust the average value of  
the Gr signal output to 150mV. Measure the average values of the Gr signal output, Gb signal output, R  
signal output and B signal output (Gra, Gba, Ra, Ba), and then adjust the luminous intensity to 500 times  
the intensity with the average value of the Gr signal output, 150mV. After the readout clock is stopped and  
the charge drain is executed by the electronic shutter at the respective H blankings, measure the maximum  
value (VSm [mV]) independent of the Gr, Gb, R and B signal outputs, and substitute the values into the  
following formula.  
Gra + Gba + Ra + Ba  
4
1
500  
1
10  
– 12 –  
Sm = Vsm ÷  
×
×
× 100 [%] (1/10V method conversion value)