欢迎访问ic37.com |
会员登录 免费注册
发布采购

ICX405AL 参数 Datasheet PDF下载

ICX405AL图片预览
型号: ICX405AL
PDF下载: 下载PDF文件 查看货源
内容描述: 为CCIR B / W视频摄像机对角线6毫米( 1/3型) CCD图像传感器 [Diagonal 6mm (Type 1/3) CCD Image Sensor for CCIR B/W Video Cameras]
分类和应用: 传感器换能器图像传感器摄像机
文件页数/大小: 17 页 / 171 K
品牌: SONY [ SONY CORPORATION ]
 浏览型号ICX405AL的Datasheet PDF文件第5页浏览型号ICX405AL的Datasheet PDF文件第6页浏览型号ICX405AL的Datasheet PDF文件第7页浏览型号ICX405AL的Datasheet PDF文件第8页浏览型号ICX405AL的Datasheet PDF文件第10页浏览型号ICX405AL的Datasheet PDF文件第11页浏览型号ICX405AL的Datasheet PDF文件第12页浏览型号ICX405AL的Datasheet PDF文件第13页  
ICX405AL
Image Sensor Characteristics Measurement Method
Measurement conditions
1) In the following measurements, the device drive conditions are at the typical values of the bias and clock
voltage conditions.
2) In the following measurements, spot blemishes are excluded and, unless otherwise specified, the optical
black (OB) level is used as the reference for the signal output, and the value measured at point [
A] in the
drive circuit example is used.
Definition of standard imaging conditions
1) Standard imaging condition
I:
Use a pattern box (luminance: 706cd/m
2
, color temperature of 3200K halogen source) as a subject.
(Pattern for evaluation is not applicable.) Use a testing standard lens with CM500S (t = 1.0mm) as an IR cut
filter and image at F8. The luminous intensity to the sensor receiving surface at this point is defined as the
standard sensitivity testing luminous intensity.
2) Standard imaging condition
II:
Image a light source (color temperature of 3200K) with a uniformity of brightness within 2% at all angles.
Use a testing standard lens with CM500S (t = 1.0mm) as an IR cut filter. The luminous intensity is adjusted
to the value indicated in each testing item by the lens diaphragm.
1. Sensitivity
Set to standard imaging condition
I.
After selecting the electronic shutter mode with a shutter speed of
1/250s, measure the signal output (Vs) at the center of the screen and substitute the value into the
following formula.
S = Vs
×
250
50
[mV]
2. Saturation signal
Set to standard imaging condition
II.
After adjusting the luminous intensity to 10 times the intensity with the
average value of the signal output, 200mV, measure the minimum value of the signal output.
3. Smear
Set to standard imaging condition
II.
With the lens diaphragm at F5.6 to F8, adjust the luminous intensity to
500 times the intensity with the average value of the signal output, 200mV. When the readout clock is
stopped and the charge drain is executed by the electronic shutter at the respective H blankings, measure
the maximum value (VSm [mV]) of the signal output and substitute the value into the following formula.
Sm = 20
×
log
1
YSm
1
×
×
10
200
500
[dB] (1/10V method conversion value)
–9–