ILX554B
Electro-optical Characteristics
(Ta = 25°C, V
DD
= 5V, Clock frequency: 1MHz, Light source = 3200K,
IR cut filter: CM-500S (t = 1.0mm), Without S/H mode)
Item
Sensitivity 1
Sensitivity 2
Sensitivity nonuniformity
Saturation output voltage
Dark voltage average
Dark signal nonuniformity
Image lag
Dynamic range
Saturation exposure
5V current consumption
Total transfer efficiency
Output impedance
Offset level
Symbol
R1
R2
PRNU
V
SAT
V
DRK
DSNU
IL
DR
SE
I
VDD
TTE
Z
O
V
OS
Min.
180
—
—
0.8
—
—
—
—
—
—
92
—
—
Typ.
240
3500
5.0
1.0
3.0
6.0
1
333
0.004
5.0
98.0
250
2.85
Max.
300
—
10.0
—
6.0
12.0
—
—
—
10
—
—
—
Unit
V/(lx · s)
V/(lx · s)
%
V
mV
mV
%
—
lx · s
mA
%
Ω
V
Remarks
Note 1
Note 2
Note 3
—
Note 4
Note 4
Note 5
Note 6
Note 7
—
—
—
Note 8
Note)
1. For the sensitivity test light is applied with a uniform intensity of illumination.
2. Light sourse: LED
λ
= 660nm
3. PRNU is defined as indicated below. Ray incidence conditions are the same as for Note 1.
PRNU =
(V
MAX
– V
MIN
)/2
V
AVE
×
100 [%]
The maximum output of all the valid pixels is set to V
MAX
,
the minimum output to V
MIN
and the average output to V
AVE
.
4. Integration time is 10ms.
5. Typical value is used for clock pulse and readout pulse. V
OUT
= 500mV.
6.
DR =
V
SAT
V
DRK
When optical integration time is shorter, the dynamic range sets wider because dark voltage is in
proportion to optical integration time.
7.
SE =
V
SAT
R1
8. V
OS
is defined as indicated below.
D
Vout
D
D
SI
V
OS
GND
–3–