155M Bi-directional SFP Transceiver
20km point to point transmission
Low (0~0.8V):
(>0.8V, <2.0V):
High (2.0~3.465V):
Open:
Transmitter on
Undefined
Transmitter Disabled
Transmitter Disabled
Jun. 12, 2007
3. MOD-DEF 0,1,2 are the module definition pins. They should be pulled up with a 4.7k~10kΩ resistor on
the host board. The pull-up voltage shall be VccT or VccR.
MOD-DEF 0 is grounded by the module to indicate that the module is present
MOD-DEF 1 is the clock line of two wire serial interface for serial ID
MOD-DEF 2 is the data line of two wire serial interface for serial ID
4. LOS is an open collector output, which should be pulled up with a 4.7k~10kΩ resistor on the host board to
a voltage between 2.0V and Vcc+0.3V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.
In the low state, the output will be pulled to less than 0.8V.
5. These are the differential receiver outputs. They are AC-coupled 100Ω differential lines which should be
terminated with 100Ω (differential) at the user SERDES.
These are the differential transmitter inputs. They are AC-coupled, differential lines with 100Ω differential
termination inside the module.
Mechanical Design Diagram
The mechanical design diagram is shown in Figure 4.
Figure 4, Product Mechanical Design Diagram
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute
Page 8 of 10