SFF GE-PON PX20 ONU Transceiver
20km transmission
FTM-9412P-F20(G)/F20i(G)
Preliminary Data Sheet
Nov.10, 2005
Regulatory Compliance
The transceivers have been tested according to American and European product safety and electromagnetic
compatibility regulations (See Table 1). For further information regarding regulatory certification, please refer to
Flexon
TM
regulatory specification and safety guidelines, or contact with Fiberxon, Inc. America sales office listed at
the end of documentation.
Table 1 - Regulatory Compliance
Feature
Electrostatic Discharge
(ESD) to the Electrical Pins
Electromagnetic
Interference (EMI)
Immunity
Laser Eye Safety
Component Recognition
MIL-STD-883E
Method 3015.7
FCC Part 15 Class B
EN55022 Class B (CISPR 22B)
VCCI Class B
IEC 61000-4-3
FDA 21CFR 1040.10 and 1040.11
EN60950, EN (IEC) 60825-1,2
UL and CSA
Compliant with standards
Compliant with Class I laser product
Compliant with standards
Compliant with standards
Standard
Performance
Class
Ⅰ
(>500 V)
RoHS
2002/95/EC 4.1&4.2
Compliant with standards
Absolute Maximum Ratings
Absolute Maximum Ratings are those values, beyond which, some damages may occur to the devices. Exposure
to conditions above the Absolute Maximum Ratings listed in Table 2 may negatively impact the reliability of the
products.
Table 2 - Absolute Maximum Ratings
Parameter
Storage Ambient Temperature
Operating Ambient Temperature
(Note 1)
Operating Humidity
Power Supply Voltage
Input Voltage
Receiver Damaged Threshold
Soldering Temperature
Bending Radius
Pigtail Fiber Contact Temperature
30
85
Symbol
T
STG
T
OPR
H
OPR
V
CC
Min.
-40
0
-40
5
0
GND
+7
400
Max.
85
70
85
95
4
Vcc
Unit
°C
°C
%
V
V
dBm
°C
mm
°C
Note 2
FTM-9412P-F20(G)
FTM-9412P-F20i(G)
Note
Note 1: With airflow 1m/sec when ambient temperature is above 60°C
Note 2: Only for soldering by iron and 10 seconds on leads only
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute
Page 2 of 2
Doc No: DS3493001-2b