 浏览型号AM29LV640MH112RPCI的Datasheet PDF文件第26页浏览型号AM29LV640MH112RPCI的Datasheet PDF文件第27页浏览型号AM29LV640MH112RPCI的Datasheet PDF文件第28页浏览型号AM29LV640MH112RPCI的Datasheet PDF文件第29页浏览型号AM29LV640MH112RPCI的Datasheet PDF文件第31页浏览型号AM29LV640MH112RPCI的Datasheet PDF文件第32页浏览型号AM29LV640MH112RPCI的Datasheet PDF文件第33页浏览型号AM29LV640MH112RPCI的Datasheet PDF文件第34页  
D A T A S H E E T
Write “Write to Buffer”
command and
Sector Address
Write number of addresses
to program minus 1(WC)
and Sector Address
Part of “Write to Buffer”
Command Sequence
Write first address/data
Yes
WC = 0 ?
No
Abort Write to
Buffer Operation?
No
Yes
Write to buffer ABORTED.
Must write “Write-to-buffer
Abort Reset” command
sequence to return
to read mode.
Write to a different
sector address
(Note 1)
Write next address/data pair
WC = WC - 1
Write program buffer to
flash sector address
Notes:
1.
When Sector Address is specified, any address in
the selected sector is acceptable. However, when
loading Write-Buffer address locations with data, all
addresses must fall within the selected Write-Buffer
Page.
Read DQ7 - DQ0 at
Last Loaded Address
2.
3.
Yes
DQ7 may change simultaneously with DQ5.
Therefore, DQ7 should be verified.
If this flowchart location was reached because
DQ5= “1”, then the device FAILED. If this flowchart
location was reached because DQ1= “1”, then the
Write to Buffer operation was ABORTED. In either
case, the proper reset command must be written
before the device can begin another operation. If
DQ1=1, write the
Write-Buffer-Programming-Abort-Reset
command. if DQ5=1, write the Reset command.
See
Table 11
for command sequences required for
write buffer programming.
DQ7 = Data?
No
No
DQ1 = 1?
Yes
DQ5 = 1?
No
4.
Yes
Read DQ7 - DQ0 with
address = Last Loaded
Address
(Note 2)
DQ7 = Data?
No
Yes
(Note 3)
FAIL or ABORT
PASS
Figure 4.
Write Buffer Programming Operation
28
Am29LV640MH/L