D A T A S H E E T
DEVICE BUS OPERATIONS
This section describes the requirements and use of
the device bus operations, which are initiated through
the internal command register. The command register
itself does not occupy any addressable memory loca-
tion. The register is a latch used to store the com-
mands, along with the address and data information
needed to execute the command. The contents of the
register serve as inputs to the internal state machine.
The state machine outputs dictate the function of the
device. Table 1 lists the device bus operations, the in-
puts and control levels they require, and the resulting
output. The following subsections describe each of
these operations in further detail.
Table 1. Device Bus Operations
DQ8–DQ15
Addresses
(Note 2)
DQ0–
DQ7
BYTE#
= VIH
BYTE#
= VIL
Operation
CE# OE# WE# RESET#
WP#
X
ACC
X
Read
L
L
L
H
H
H
L
L
H
H
AIN
AIN
AIN
DOUT
DOUT
DQ8–DQ14
= High-Z,
DQ15 = A-1
Write (Program/Erase)
Accelerated Program
(Note 3)
(Note 3)
X
(Note 4) (Note 4)
(Note 4) (Note 4)
L
H
VHH
VCC
0.3 V
±
VCC ±
0.3 V
Standby
X
X
X
H
X
High-Z High-Z
High-Z
Output Disable
Reset
L
H
X
H
X
H
L
X
X
X
X
X
X
High-Z High-Z
High-Z High-Z
High-Z
High-Z
X
SA, A6 =L,
A3=L, A2=L, (Note 4)
A1=H, A0=L
Sector Group Protect
(Note 2)
L
H
L
VID
H
X
X
X
X
SA, A6=H,
A3=L, A2=L, (Note 4)
A1=H, A0=L
Sector Group Unprotect
(Note 2)
L
H
X
L
VID
VID
H
H
X
X
X
Temporary Sector
Group Unprotect
X
X
AIN
(Note 4) (Note 4)
High-Z
Legend: L = Logic Low = VIL, H = Logic High = VIH, VID = 11.5–12.5 V, VHH = 11.5–12.5 V, X = Don’t Care, SA = Sector Address,
AIN = Address In, DIN = Data In, DOUT = Data Out
Notes:
1. Addresses are A21:A0 in word mode; A21:A-1 in byte
mode. Sector addresses are A21:A15 in both modes.
unprotected as determined by the method described in
“Sector Group Protection and Unprotection”. All sectors are
unprotected when shipped from the factory (The SecSi
Sector may be factory protected depending on version
ordered.)
2. The sector protect and sector unprotect functions may also
be implemented via programming equipment. See the
“Sector Group Protection and Unprotection” section.
4. DIN or DOUT as required by command sequence, data
polling, or sector protect algorithm (see Figure 2).
3. If WP# = VIL, the first or last sector remains protected. If
WP# = VIH, the first or last sector will be protected or
10
Am29LV640MH/L