SZN5063 thru SZN5117 Series
Solid State Devices, Inc.
14701 Firestone Blvd * La Mirada, Ca 90638
Phone: (562) 404-4474 * Fax: (562) 404-1773
ssdi@ssdi-power.com * www.ssdi-power.com
Electrical Characteristics @ 25°C
Nominal
Zener
Voltage
(note 1)
Zener
Test Current
Maximum
Zener
Impedance
(note 2)
Maximum
Regulation
Maximum
Maximum Reverse
Leakage Current
(note 8)
Forward
Voltage
Drop @
1A
Continuous Iz = 10% to Surge Current
Current
(note 3)
PART
NUMBER
50% of Iz
max
(note 4)
VZ @ IZT
V
IZT
mA
ZZ @ IZT
IZM
mA
∆Vz
IFSM
A
VR
V
IR
Vf
V
Ω
V
µA
SZN5098
SZN5099
SZN5100
SZN5101
SZN5102
130
140
160
170
180
98.8
1
1
1
1
1
5.0
5.0
4.0
4.0
4.0
375
550
700
750
850
20
20
20
18
18
14
14
16
16
17
0.20
0.20
0.15
0.15
0.10
1.5
1.5
1.5
1.5
1.5
106.4
121.6
129.2
136.8
SZN5103
SZN5104
SZN5105
SZN5106
SZN5107
190
200
220
240
260
4.0
4.0
3.0
3.0
3.0
900
950
1100
1300
1500
15
15
15
12
12
17
17
18
21
21
0.10
0.10
0.09
0.09
0.08
144.7
152.0
167
182
198
1
1
1
1
1
1.5
1.5
1.5
1.5
1.5
SZN5108
SZN5109
SZN5110
SZN5111
SZN5112
270
280
300
320
330
3.0
3.0
3.0
2.0
2.0
1600
1700
1900
2100
2250
10
10
10
9
22
23
26
26
30
0.08
0.08
0.07
0.07
0.06
206
213
228
244
251
1
1
1
1
1
1.5
1.5
1.5
1.5
1.5
9
SZN5113
SZN5114
SZN5115
SZN5116
SZN5117
340
360
380
390
400
2.0
2.0
2.0
2.0
2.0
2400
2700
3000
3250
3500
8
8
8
7
7
33
33
34
37
40
0.06
0.06
0.06
0.06
0.06
259
274
289
297
304
1
1
1
1
1
1.5
1.5
1.5
1.5
1.5
NOTES:
1/ All zener voltages are measured with an automated test set using a 20-50 msec test time. Longer or shorter test time will have a corresponding
effect on the measured value due to heating effects.
2/ Zener impedance is derived from the AC voltage divided by the AC current with RMS value of 10% of DC zener test current superimposed on the
test current.
3/ Ratings based on maximum zener voltage of individual units (leaded units).
4/ Figures shown are for a peak sinusoidal surge current of 8.3 msec duration, non-repetitive. The 8.3 msec square pulse rating is 71% of the value
shown.
5/ SSDI standard marking consists of a contrasting color cathode dot or band. Part number information is included on packaging labels.
6/ For Ordering Information, Price, and Availability- Contact Factory.
7/ Screening based on MIL-PRF-19500. Screening flows available on request.
8/ For 10% tolerance devices, reduce Vr test voltage by 5%
NOTE: All specifications are subject to change without notification.
SCD's for these devices should be reviewed by SSDI prior to release.
DATA SHEET #: Z00009E
DOC