SMB113A/B/SMB117/A
Preliminary Information
DC OPERATING CHARACTERISTICS (CONTINUED)
(Over recommended operating conditions, unless otherwise noted. All voltages are relative to GND.)
Symbol
Parameter
Conditions
Programmable UV1 threshold
voltage measured on VBATT pin
in 150 mV increments
Programmable UV2 threshold
voltage measured on VBATT pin
in 150 mV increments
Min
Typ
Max
Unit
Programmable Monitoring Thresholds
V
PUV1
V
PUV2
∆V
PUV2
∆V
PUV1
Programmable UV1 threshold
Programmable UV2 threshold
UV2 accuracy
UV1 accuracy
-3
P
UVTH
Programmable under-voltage
threshold
Output voltage relative to
nominal operating voltage.
Note 3.
-8
-12
-16
+3
P
OVTH
Programmable over-voltage
threshold
Output voltage relative to
nominal operating voltage.
Note 3.
+8
+12
+16
2.55
2.55
±2
±2
-5
-10
-15
-20
+5
+10
+15
+20
-7
-12
-18
-24
+7
+12
+18
+24
%
%
3.60
3.60
V
V
%
%
Note 1: Voltage accuracies are only guaranteed for factory-programmed settings. Changing the output voltage from that reflected in the customer
specific CSIR code might result in inaccuracies exceeding those specified above by 1%.
Note 2: For more accurate active current levels under several load conditions, Summit’s proprietary design software can be used. Contact the
factory for more information.
Note 3: Guaranteed by Design and Characterization – not 100% tested in Production.
Summit Microelectronics, Inc
2111 2.4 6/24/2008