SMH4814
Preliminary Information
PIN DESCRIPTION (CONTINUED)
Pin No.
QFN
18
Pin Type
I
Name
FEED
A
Description
Connect to the -48V 'A' feed using a series 100k resistor. The voltage on
this pin is compared with the voltage on the FEED
B
pin internally by the
supply arbitration logic to determine which voltage will be used.
The DRAIN SENSE input monitors the voltage at the drain of the external
power MOSFET switch with respect to VSS. An internal 10µA source pulls
the DRAIN SENSE signal towards the 5V_CAP level. DRAIN SENSE must
be held below 2.5V to enable the PUP
X
outputs.
External capacitor input used to filter the device’s internal operating supply.
Also a hold Capacitor to sequence down and to filter any power glitches.
The VGATE_HS output activates an external power MOSFET switch. This
signal controls inrush current by modulating the gate of the Hot Swap
MOSFET device. It supplies a programmable current output which allows
easy adjustment of the MOSFET turn-on slew rate.
This pin controls the gate of the active FET on FEED
B
.
This pin controls the gate of the active FET on FEED
A
This is the positive supply input. An internal shunt regulator limits the
voltage on this pin to approximately 12V with respect to V
SS
. A resistor
must be placed in series with the V12 pin to limit the regulator current (R
D
in
the application schematics).
Active-high, logic level input that can be used to indicate when the converter
controlled by PUP
D
is fully powered. A hold-off timer allows the secondary
side (which is not powered up initially) to control shut down via an opto-
isolator. See Figures 5 and 6.
Active-high, logic level input that can be used to indicate when the converter
controlled by PUP
C
is fully powered. A hold-off timer allows the secondary
side (which is not powered up initially) to control shut down via an opto-
isolator. See Figures 5 and 6.
Active-high, logic level input that can be used to indicate when the converter
controlled by PUP
B
is fully powered. A hold-off timer allows the secondary
side (which is not powered up initially) to control shut down via an opto-
isolator. See Figures 5 and 6.
Active-high, logic level input that can be used to indicate when the converter
controlled by PUP
A
is fully powered. A hold-off timer allows the secondary
side (which is not powered up initially) to control shut down via an opto-
isolator. See Figures 5 and 6.
19
I
DRAIN
SENSE
5V_CAP
VGATE_HS
20
21
O
O
22
23
24
O
O
PWR
VGATE
B
VGATE
A
V12
25
I
FB
D
26
I
FB
C
27
I
FB
B
28
I
FB
A
Summit Microelectronics, Inc
2080 2.0 07/21/05