 浏览型号DQ63318QGL08NYS的Datasheet PDF文件第1页浏览型号DQ63318QGL08NYS的Datasheet PDF文件第2页浏览型号DQ63318QGL08NYS的Datasheet PDF文件第3页浏览型号DQ63318QGL08NYS的Datasheet PDF文件第5页浏览型号DQ63318QGL08NYS的Datasheet PDF文件第6页浏览型号DQ63318QGL08NYS的Datasheet PDF文件第7页浏览型号DQ63318QGL08NYS的Datasheet PDF文件第8页浏览型号DQ63318QGL08NYS的Datasheet PDF文件第9页  
Technical Specification  
Quarter  
48V 3.3/1.8V  
77W  
out  
in  
Brick Dual  
ELECTRICAL CHARACTERISTICS (Continued)  
Parameter  
P
Min.  
Typ.  
Max.  
Units Notes & Conditions  
ISOLATION CHARACTERISTICS  
Isolation Voltage  
2000  
30  
V
Isolation Resistance  
M
Isolation Capacitance  
3300  
pF  
FEATURE CHARACTERISTICS  
Switching Frequency  
230  
260  
290  
kHz  
ON/OFF Control (Option P)  
Off-State Voltage  
-2  
0.8  
18  
V
V
On-State Voltage  
2.4  
ON/OFF Control (Option N)  
Off-State Voltage  
2.4  
-2  
18  
V
V
On-State Voltage  
0.8  
ON/OFF Control (Either Option)  
Pull-Up Voltage  
Figures A, B  
Vin/6.5  
40  
9.2  
V
Pull-Up Resistance  
k
Output Voltage Trim Range  
Output Over-Voltage Protection (1.8V)  
Output Over-Voltage Protection (3.3V)  
Over-Temperature Shutdown  
Over-Temperature Shutdown Restart Hysteresis  
RELIABILITY CHARACTERISTICS  
Calculated MTBF (Telcordia)  
Calculated MTBF (MIL-217)  
Demonstrated MTBF  
-10  
111  
111  
+10  
125  
125  
%
Trim-up pins 6-5, Trim-down pins 6-4; Fig D  
Over full temp range  
117  
117  
125  
10  
%
%
Over full temp range  
°C  
°C  
Average PCB Temperature  
106 Hrs. TR-NWT-000332; 80% load,300LFM, 40 C T  
o
TBD  
TBD  
TBD  
a
a
106 Hrs. MIL-HDBK-217F; 80% load, 300LFM, 40 C T  
o
106 Hrs. Field demonstrated MTBF  
STANDARDS COMPLIANCE  
Parameter  
P
Notes  
STANDARDS COMPLIANCE  
UL/cUL 60950  
File # E194341, Basic insulation & pollution degree 2  
Certified by TUV  
EN60950  
72/23/EEC  
93/68/EEC  
Needle Flame Test (IEC 695-2-2)  
IEC 61000-4-2  
test on entire assembly; board & plastic components UL94V-0 compliant  
ESD test, 8kV - NP, 15kV air - NP  
GR-1089-CORE  
Section 7 - electrical safety, Section 9 - bonding/grounding  
Telcordia (Bellcore) GR-513  
An external input fuse must always be used to meet these safety requirements  
QUALIFICATION TESTING  
Parameter  
P
# Units Test Conditions  
QUALIFICATION TESTING  
Life Test  
32  
95% rated Vin and load, units at derating point, 1000 hours  
10-55Hz sweep, 0.060” total excursion,1 min./sweep, 120 sweeps for 3 axis  
100g minimum, 2 drops in x and y axis, 1 drop in z axis  
-40°C to 100°C, unit temp. ramp 15°C/min., 500 cycles  
Toperating = min to max, Vin = min to max, full load, 100 cycles  
Tmin-10°C to Tmax+10°C, 5°C steps, Vin = min to max, 0-105% load  
85°C, 85% RH, 1000 hours, 2 minutes on and 6 hours off  
MIL-STD-883, method 2003  
Vibration  
5
Mechanical Shock  
Temperature Cycling  
Power/Thermal Cycling  
Design Marginality  
Humidity  
5
10  
5
5
5
Solderability  
15 pins  
Extensive characterization testing of all SynQor products and manufacturing processes is performed to ensure that we supply  
robust, reliable product. Contact factory for more information about Proof of Design and Proof of Manufacturing processes.  
OPTIONS  
PATENTS  
SynQor provides various options for Logic Sense, Pin Length and SynQor is protected under various patents, including but not lim-  
Feature Set for this family of DC/DC converters. Please consult the ited to U.S. Patent # 5,999,417.  
last page of this specification sheet for information on available  
options.  
Product # DQ63318QGL08  
Phone 1-888-567-9596  
Doc.# 005-2DQ638D Rev. B  
10/7/03  