Input: 18-36V
Output: 24 V
Current: 9.0 A
Part No.: IQ24240HPx09
Technical Specification
100
95
90
85
80
75
70
65
60
24
21
18
15
12
9
6
18 Vin
24 Vin
36 Vin
18 Vin
24 Vin
36 Vin
3
0
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for
Figure 2: Power dissipation at nominal output voltage vs. load current
minimum, nominal, and maximum input voltage at 25
°C.
for minimum, nominal, and maximum input voltage at 25°C.
10
9
10
9
8
8
7
7
6
6
5
5
4
4
3
2
1
0
3
2
1
0
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
25
40
55
Ambient Air Temperature (°C)
70
85
25
40
55
Ambient Air Temperature (°C)
70
85
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%-50%
Figure 6: Output voltage response to step-change in input voltage
of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1
µF ceramic and 15
µF tantalum
(500 V/ms). Load cap: 100 µF, electrolytic output capacitance.
capacitors. Ch 1: Vout (500 mV/div), Ch 2: Iout (2 A/div).
Ch 1: Vout (2 V/div), Ch 2: Vin (20 V/div).
Product # IQ24xxxHPxxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005229 Rev. A
05/26/09
Page 17