P
STANDARDS COMPLIANCE
STANDARDS COMPLIANCE
UL/cUL 60950-1
EN60950-1
Needle Flame Test (IEC 695-2-2)
IEC 61000-4-2
LIM
RE
I
RY
NA
Technical
Specification
IQ32-HPC Family
Parameter
Notes & Conditions
File # E194341, Basic insulation
Certified by TUV
Test on entire assembly; board & plastic components UL94V-0 compliant
ESD test, 8 kV - NP, 15 kV air - NP (Normal Performance)
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new
releases or download from the SynQor website.
QUALIFICATION TESTING
QUALIFICATION TESTING
Life Test
Vibration
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
Solderability
Parameter
# Units
32
5
5
10
5
5
5
15 pins
Test Conditions
95% rated Vin and load, units at derating point, 1000 hours
10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis
100g minimum, 2 drops in x and y axis, 1 drop in z axis
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles
Toperating = min to max, Vin = min to max, full load, 100 cycles
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load
85 °C, 85% RH, 1000 hours, continuous Vin applied except 5 min/day
MIL-STD-883, method 2003
Product # IQ32xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005H332 Rev. 1
08/13/08
Page 4