 浏览型号IQ65033QMA10ENS-G的Datasheet PDF文件第1页浏览型号IQ65033QMA10ENS-G的Datasheet PDF文件第2页浏览型号IQ65033QMA10ENS-G的Datasheet PDF文件第3页浏览型号IQ65033QMA10ENS-G的Datasheet PDF文件第4页浏览型号IQ65033QMA10ENS-G的Datasheet PDF文件第6页浏览型号IQ65033QMA10ENS-G的Datasheet PDF文件第7页浏览型号IQ65033QMA10ENS-G的Datasheet PDF文件第8页浏览型号IQ65033QMA10ENS-G的Datasheet PDF文件第9页  
Technical Specification
Input:
Outputs:
Current:
Package:
36-75 V
5.0 V/ 3.3 V
10 A
Quarter-brick
IQ65033QMA10 ELECTRICAL CHARACTERISTICS (Continued)
Parameter
P
I
2
C
DATA REPORTING INTERFACE
Maximum Clock Rate
Measurement Error
Feed Voltage A/B
Holdup Voltage
-48V_OUT Current
Temperature
OVER-TEMPERATURE PROTECTION
Shutdown Point
Restart Hysteresis
RELIABILITY CHARACTERISTICS
Calculated MTBF (Telcordia)
Calculated MTBF (MIL-217)
Field Demonstrated MTBF
Specifications subject to change without notice. Specifications in
bold
are guaranteed by design over the temperature range -40º to 125ºC.
Min.
Typ.
100
Max.
400
+3
+3
+3
+3
Units
kHz
%
%
%
°C
°C
°C
Notes & Conditions
Clock stretching happens at the maximum rate
135
10
3.6
3.27
Does not shut down Management Power
Automatic restart
10
6
Hrs. TR-NWT-000332; 80% load,300LFM, 40oC Ta
10
6
Hrs. MIL-HDBK-217F; 80% load, 300LFM, 40oC Ta
10
6
Hrs. See website for details
STANDARDS COMPLIANCE
Parameter
P
Notes
File # E194341, Basic insulation & pollution degree 2
Certified by TUV
Test on entire assembly; board & plastic components UL94V-0 compliant
ESD test, 8kV - NP, 15kV air - NP (Normal Performance)
Section 7 - electrical safety, Section 9 - bonding/grounding
STANDARDS COMPLIANCE
UL/cUL 60950-1
EN60950-1
72/23/EEC
93/68/EEC
Needle Flame Test (IEC 695-2-2)
IEC 61000-4-2
GR-1089-CORE
Telcordia (Bellcore) GR-513
• An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety
certificates on new releases or download from the SynQor website.
QUALIFICATION TESTING
Parameter
P
# Units
32
5
5
10
5
5
5
15 pins
Test Conditions
10-55Hz sweep, 0.060” total excursion,1 min./sweep, 120 sweeps for 3 axes
QUALIFICATION TESTING
Life Test
Vibration
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
Solderability
95% rated V
in
and load, units at derating point, 1000 hours
100g minimum, 2 drops in x and y axis, 1 drop in z axis
-40°C to 100°C, unit temp. ramp 15°C/min., 500 cycles
T
operating
= min to max, V
in
= min to max, full load, 100 cycles
T
min
-10°C to T
max
+10°C, 5°C steps, V
in
= min to max, 0-105% load
85°C, 85% RH, 1000 hours, 2 minutes on and 6 hours off
MIL-STD-883, method 2003
• Extensive characterization testing of all SynQor products and manufacturing processes is performed to ensure that we supply
robust, reliable product. Contact the factory for official product family qualification documents.
Product # IQ65033QMA10
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-IQ5033S Rev. G
05/04/09
Page 5