MQME-270-P
Current:
2A
Technical Specification
20
0
-20
100
Output Impedance Magnitude (ohms)
ad
pu
va
bl
ic n
at ce
io d
n
Attenuation (dB)
-40
-60
-80
1
-100
-120
-140
-160
-180
0.1
Common Mode
Differential Mode
0.1
1
0.01
0.01
10
100
1000
10000
100000
0.01
0.1
1
10
100
10
1000
Frequency (kHz)
Frequency (kHz)
Figure 1: Typical Common Mode and Differential Mode Attenuation
provided by the filter as a function of frequency. Both input lines are
connected to chassis ground through 50ohm resistors. The filter case is
also connected to chassis ground.
Figure 2: Typical Output Impedance (magnitude) of the filter looking
back into its output pins with the input pins connected to a source with
zero source impedance.
Figure 3: MIL-STD-461E Method CE101 Low Frequency Conducted
Emissions. Limit line (in red) is the ‘Submarine Applications DC Curve’.
Figure 4: MIL-STD-461E Method CE102 High Frequency Conducted
Emissions. Limit line (in red) is the ‘Basic Curve’.
Figure 5: MIL-STD-461E Method RE101 Low Frequency Radiated
Emissions. Limit line (in red) is the ‘Standard Curve’ from MIL-STD-
461C Method RE01, which is more strict than all RE101 limits.
Phone 1-888-567-9596
Figure 6: MIL-STD-461E Method RE102 High Frequency Radiated
Emissions. Limit line (in red) is the ‘Submarine External to Pressure
Hull Curve’.
Doc.# 005-2ME027P Rev. 2
03/16/09
Product # MQME-270-P
www.synqor.com