MQME-28-P
Current:
20 A
Technical Specification
VOLTAGE SURGE AND SPIKE COMPLIANCE MATRIX
These tables show the Voltage Surge and Spike requirements/limits that have been met* by a stand-alone setup comprised of:
- MQME-28-P (or –T) Filter
- MQFL-28-05S DC/DC Converter
- 120W Resistive Load
- Metal Chassis Plane
Worst Case Over-Voltage Surge
Short Duration Spikes
(Voltage/Duration/Impedance)
Vehicle 28Vin
(Voltage/Duration)
MIL-STD-1275B (Gen.+Bat.)
40V/ 50ms
100V/ 50ms
100V/ 50ms
±250V / 15mJ / 0.5
±250V / 15mJ / 0.5
±250V / 15mJ / 0.5
Ω
Ω
Ω
MIL-STD-1275B (Bat. Only)
MIL-STD-1275B (Gen. Only)
/
40V 50ms
+130V/-100V max
+90V/-60V / 10µs
†
DEF STAN 61-5 (PART 6)/5 (Gen.+Bat.)
+70V/-40V/ 5ms
40V/ 50ms
+130V/-100V max
+90V/-60V / 10µs
†
DEF STAN 61-5 (PART 6)/5 (Bat. Only, Regen. Ld. Sw.)
+70V/-40V/ 5ms
100V/ 80ms
+130V/-100V max
+90V/-60V / 10µs
†
DEF STAN 61-5 (PART 6)/5 (Bat. Only, Non-Regen. Ld. Sw.)
+70V/-40V/ 5ms
100V/ 80ms
+280V/-220V max
+130V/-70V / 10µs
†
DEF STAN 61-5 (PART 6)/5 (Gen. Only)
+110V/-50V/ 5ms
Worst Case Over-Voltage Surge
Short Duration Spikes
(Voltage/Duration/Impedance)
Aircraft 28Vin
(Voltage/Duration)
80V/ 50ms
60V/ 550ms
50V/ 50ms
MIL-HDBK-704-8 ( 704A)
N/A
MIL-HDBK-704-8 (704B)
MIL-HDBK-704-8 (704C)
MIL-HDBK-704-8 (704D)
MIL-HDBK-704-8 (704E)
MIL-HDBK-704-8 (704F)
N/A
N/A
N/A
N/A
N/A
/
50V 50ms
50V/ 50ms
50V/ 50ms
50V/ 50ms
47V/ 100ms
38V/ 1 sec
60V/ 100ms
40V/ 1 sec
RTCA/DO-160E (Cat. A)
RTCA/DO-160E (Cat. B)
RTCA/DO-160E (Cat. Z)
±600V / 10µs / 50
±200V / 10µs / 50
N/A
Ω
Ω
/
80V 100ms
48V/ 1 sec
Met by an MQME Filter having the
Transient Suppression and Reverse
Polarity Protection Features
Met by any MQME Filter
* Surge/spike requirements/limits are deemed to have been met as long as transient deviations in the converter’s output voltage
remain within 10% of its initial value.
† For the DEF STAN 61-5 specification:
1) Negative surges require reverse voltage protection circuitry to protect the converter (but not the filter) from a negative input.
This circuitry is included in the MQME-28-T and MQME-28-HT filters but not the MQME-28-P filter.
2) The negative surges may cause the converter to shut down unless additional holdup capacitance is included.
3) Maximum spike voltages are assumed to last <1µs.
Product # MQME-28-P
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2ME028P Rev. A
5/1/08