Engineering Specifications
Ordering Information
Manifold Model Number Pipe Size
Pump Voltage
110V
Flow Switch
WFD20
General/Retrofit Model Specifications
ZC20
2″
Model shall be a Zonecheck Flow Switch
/
Tester model ___________________ as manufac-
tured by System Sensor. Flow Switch Tester
shall be installed on a sprinkler system riser as
designated on the drawings and/or as speci-
fied herein. Flow Switch Tester assembly shall
mount on any clear pipe span of the appropri-
ate nominal size, either in a vertical upflow or
horizontal run, between 6″ and 12″ from the
ZC25
21 2″
3″
110V
WFD25
ZC30
110V
WFD30-2
WFD40
ZC40
4″
110V
ZC20A
ZC25A
ZC30A
2″
110V
WFD20A
WFD25A
WFD30-2A
WFD40A
Flow Switch
WFD20
21 2″
/
110V
3″
110V
flow switch. Flow Switch Tester shall consist of ZC40A
a recirculating pump, operating at nominal
4″
110V
Retrofit Model Number
Pipe Size
Pump Voltage
110V
110V or 220V as appropriate, two (2) sets of
valves and elbows to facilitate the circulation
of the water, a System Sensor vane-type water-
flow detector, and a key switch to activate the
recirculating pump. When activated, the pump
shall circulate the water within the sprinkler
riser around the waterflow detector vane to
simulate the flow of one sprinkler head in oper-
ation. The activating key switch shall provide
the means to be wired locally to one
Zonecheck Flow Switch Tester, or intercon-
nected with other key switches for group
activation. Flow Switch Tester shall be avail-
able for manifold and retrofit installation
applications. Zonecheck Flow Switch Tester
retrofit models shall be listed by Underwriters
Laboratories, Inc.
ZCR20
2″
/
ZCR25
2 1 2″
110V
WFD25
ZCR30
3″
4″
6″
8″
2″
110V
WFD30-2
WFD40
ZCR40
110V
ZCR60
110V
WFD60
ZCR80
110V
WFD80
ZCR20A
ZCR25A
ZCR30A
ZCR40A
ZCR60A
ZCR80A
ZCR20E
ZCR25E
ZCR30E
ZCR40E
ZCR60E
ZCR80E
110V
WFD20A
WFD25A
WFD30-2A
WFD40A
WFD60A
WFD80A
WFD20E
WFD25E
WFD30E
WFD40E
WFD60E
WFD80E
21 2″
/
110V
3″
110V
4″
110V
6″
110V
8″
110V
50 mm
65 mm
80 mm
100 mm
150 mm
200 mm
220V
Manifold Model Specifications
220V
Zonecheck Automatic Flow Switch Tester mani-
fold models shall further consist of a schedule
10 pipe assembly of the appropriate nominal
size. Manifold assembly shall provide grooved
ends for accepting the appropriate grooved
connection fittings. Manifold assembly shall
include no less than two drain ports with the
appropriate drain plugs. Manifold Zonecheck
models shall come with the pump, valves,
elbows, pipe assembly, drain plugs, and System
Sensor waterflow detector pre-assembled.
Zonecheck Flow Switch Tester manifold models
shall be listed by Underwriters Laboratories,
Inc.
220V
220V
220V
220V
Replacement Model No. Description
ZCK-1
110V Keyswitch
220V Keyswitch
ZCK-1E
ZCK-1EG
ZCP-110
ZCP-220
ZCRK
220V Keyswitch (German)
110V Pump
220V Pump
Zonecheck Replacement Kit
System Sensor Sales and Service
System Sensor Headquarters
3825 Ohio Avenue
St. Charles, IL 60174
Ph: 800/SENSOR2
Fx: 630/377-6495
Documents-on-Demand
800/736-7672 x3
System Sensor Canada
Ph: 905.812.0767
Fx: 905.812.0771
System Sensor in China
Ph: 86.29.524.6253
Fx: 86.29.524.6259
System Sensor – Far East
Ph: 85.22.191.9003
Fx: 85.22.736.6580
System Sensor – India
Ph: 91.124.637.1770 x.2700
Fx: 91.124.637.3118
System Sensor Europe
Ph: 44.1403.276500
Fx: 44.1403.276501
System Sensor in Singapore
Ph: 65.6273.2230
Fx: 65.6273.2610
System Sensor – Australia
Ph: 613.54.281.142
Fx: 613.54.281.172
www.systemsensor.com
© 2003 System Sensor. The company reserves the right to change product specifications without notice.
A05-0272-003•02/03•#1070