欢迎访问ic37.com |
会员登录 免费注册
发布采购

BS24D4A 参数 Datasheet PDF下载

BS24D4A图片预览
型号: BS24D4A
PDF下载: 下载PDF文件 查看货源
内容描述: 4A至600 VAC SIP封装DC控制 [4A to 600 Vac SIP Package DC Control]
分类和应用: 光电输出元件
文件页数/大小: 2 页 / 87 K
品牌: TELEDYNE [ TELEDYNE TECHNOLOGIES INCORPORATED ]
 浏览型号BS24D4A的Datasheet PDF文件第2页  
Series BS
4A to 600 Vac SIP Package
DC Control
Part Number
BS24D4A
BS24D4F
BS60D4A
Description
4A, 280 Vac
4A, 280 Vac
4A, 600 Vac
Part Number Explanation
BS
24
D
4
A
NOTES
1) Line Voltage: 24 = 280 Vac; 60 = 600 Vac
2) Switch Type: D = Zero-cross turn-on
3) Control Range: A = 3.0–10 Vdc for BS24D4A, 3.7–10 Vdc for
BS60D4A; F = 8–30 Vdc
FEATURES/BENEFITS
• Industry standard package
• High in-rush capabilities
• Low input current draw
• High dv/dt capability
DESCRIPTION
The BS 4-amp solid-state single inline (SIP) four-pin
relays are designed for mounting on a printed circuit
board. The BS relays can withstand very high current
overloads. The compact size and triac output make
the BS relay an excellent choice for switching medium-
power resistive loads.
APPLICATIONS
• Interface applications
• Vending machines
• Light/lamp control
• HVAC controls
APPROVALS
All models are UL recognized. VDE approved.
UL File Number: E128555.
MECHANICAL SPECIFICATION
1.70 (43.2)
±.02
±
0.01
.39 (10.2)
±
0.01
.98 (25.4)
- +
±.02
.19 (6.5)
.30
(7.63)
.49
±.001
.40
±.001
(12.7) (10.16)
WEIGHT: 0.7 oz. (20g)
Ø1
.20
±.001
(5.08)
.30
(7.62)
Figure 1 – BS relays; dimensions in inches (mm)
INPUT (CONTROL) SPECIFICATION
Min
Control Range
BS24D4A
BS24D4F
BS60D4A
Input Current Range
Must Turn-Off Voltage
BS24D4A
BS24D4F
BS60D4A
Input Resistance (Typical)
BS24D4A
BS24D4F
BS60D4A
© 2003 TELEDYNE RELAYS
Max
10
30
10
30
Units
Vdc
Vdc
Vdc
mAdc
BLOCK DIAGRAM
3
8
3.7
5
3+
1~
4–
Figure 2 – BS relays
0.8
0.8
1.5
Vdc
Vdc
Vdc
2~
330
1200
270
Ohms
Ohms
Ohms
BS 1
BS\032003\Q1
(800) 284-7007 • www.teledynerelays.com