Series DR
SURGE CURRENTS
250
200
Non-Repetitive
Apeak
150
100
50
Repetitive with initial Tj = 70˚C
0
0.01
0.1
1
10
t (s)
Figure 5a — DR24 relays
600
Non-Repetitive
Apeak
400
200
Repetitive with initial Tj = 70˚C
0
0.01
0.1
1
10
t (s)
Figure 5b — DR48X25 relays
1500
Non-Repetitive
Apeak
1000
500
Repetitive with initial Tj = 70˚C
0
0.01
0.1
1
10
t (s)
Figure 5c — DR48D30 relay
DIN-RAIL MOUNTING
NOTES:
1. Connections: For output terminals, the wire cross sections must be
adapted to the load current and to the overcurrent protection device
characteristics. The relay rated voltage must be adapted to the mains
rated voltage. These relays use screw clamp connections.
2. Mounting: Only in vertical position.
Protect heat-sensitive materials as well
as people from contact with the heat
sink. For non vertical mounting, the
load current must be derated by 50% .
The SSR requires air convection. Lack
of air convection produces an abnormal
heating. Keep a distance between the
upper SSR and the lower SSR (see
vertical
3.15 inches
figure on the right). In case of zero
position
(80mm)
space between two SSRs, reduce the
load current. It’s suggested to maintain
the heat sink temperature under 90°C.
Forced cooling significantly improves
the thermal performances.
3. Typical application loads: The DR relay
may handle motor and resistive loads.
For different loads, check the inrush
current at turn-ON and possible overvoltages at turn-OFF or contact
the factory.
• Incandescent lamps — Inrush current is generally 10 times the
current nominal for 10ms.
• Electric discharge lamp — These loads often have overcurrent at
turn-ON and overvoltage at turn-OFF. Use 480Vac SSR on 240Vac
mains.
• Transformer loads — Very high inrush current, up to 100 times the
nominal current.
• Capacitive loads — Very high current at turn-On and overvoltage at
turn-Off. Use only zero-cross models.
4. Protection: To protect the SSR against a short-circuit
1~
of the load, use a fuse with a I
2
t value = 1/2 I
2
t value.
Fuse
5. EMC:
Immunity: lmmunity levels of the DR comply with
EN61000-4-4 &5.
L1
Emission: The system integrator must ensure that
systems containing SSRs comply with the
requirements of any rules and regulations applicable
T1
at the system level. The very low zero-cross voltage
+
(<20V) improves the conducted emission level in
Load
comparison with most SSRs with zero-cross voltage
higher than 50V.
N
6. All electrical parameters specified at 25°C unless
otherwise noted.
A1
A2
control
Mounting
Recommended to connect
DIN rail to ground.
Dismounting
Figure 6 — DR relay
PANEL MOUNTING
M5
M4
CONNECTIONS
Drill for vertical can be adjusted
L
wires
(mm
2
)
L
torques
screwdriver
3.47±.08
(88±2)
control
1 x (0.75-->2.5)
L = 6mm
0.4N.m
(0.6N.m max)
3.5 x 0.5mm
Power
1 x (1.5-->16) 1 x (1.5-->10)
L = 10mm
.5 (12.7)
1.2N.m
(1.8N.m max)
Pozidriv2/
0.8 x 5.5 (1 x 6)
Figure 7 — DR relay
DR 4
Figure 8 — DR relay
© 2003 TELEDYNE RELAYS
DR\032003\Q1
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE