SPeCIFICATIONS
HDO4022
Vertical
Bandwidth (@ 50Ω)
Rise time
Input Channels
Vertical Resolution
Sensitivity
DC Gain Accuracy
BW Limit
Maximum Input Voltage
Input Coupling
Input Impedance
Offset Range
200 MHz
1.75 ns typical
350 MHz
1 ns typical
2
4
2
4
12-bits; up to 15-bits with enhanced resolution (ERES)
50
Ω:
1mV/div - 1 V/div; 1 MΩ: 1 mV/div - 10 V/div
±(0.5%) Full Scale, offset at 0 V
20 MHz, 200 MHz
50
Ω:
5 Vrms; 1 MΩ: 400 V max (DC + Peak AC
10 kHz)
50
Ω:
DC, GND; 1 MΩ: AC, DC, GND
50
Ω
±2.0%, 1 MΩ ±2.0% || 15 pF
50
Ω:
1 mV - 4.95 mV: ±1.6 V, 5 mV - 9.9 mV: ±4 V, 10 mV - 19.8 mV: ±8 V, 20 mV - 1 V: ±10 V
1 MΩ: 1 mV - 4.95 mV: ±1.6 V, 5 mV - 9.9 mV: ±4 V, 10 mV - 19.8 mV: ±8 V, 20 mV - 100 mV: ±16 V,
102 mV - 198 mV: ±80V, 200 mV - 1 V: ±160 V, 1.02 V -10 V: ±400 V
±(1.0% of offset value + 0.5%FS + 0.02% of max offset + 1 mV)
500 MHz
700 ps typical
4
1 GHz
450 ps typical
4
HDO4024
HDO4032
HDO4034
HDO4054
HDO4104
Offset Accuracy
Acquisition
Sample Rate (Single-shot)
Sample Rate (Repetitive)
Record Length
Acquisition Modes
Timebase Range
Timebase Accuracy
2.5 GS/s
125 GS/s
Standard -STD: 12.5 Mpts/ch (all channels) 25 Mpts (interleaved)
Optional -L:
25 Mpts/ch (all channels), 50 Mpts (interleaved)
Real Time, Roll, RIS (Random Interleaved Sampling),
Sequence (Segmented Memory up to 10,000 segments with 1μs intersegment time)
20 ps/div–10000 s/div; RIS available at
10 ns/div; Roll Mode available at
100 ms/div and
5 MS/s
±2.5 ppm for 5 to 40C + 1.0 ppm/year from calibration
Trigger System
Modes
Sources
Coupling
Pre-trigger Delay
Post-trigger Delay
Hold-off
Internal Trigger Level Range
External Trigger Level Range
Trigger Types
Auto, Normal, Single, Stop
Any input channel, External, Ext/10, or line; slope and level unique to each source (except for line trigger)
DC, AC, HFREJ, LFREJ
0-100% of full scale
0-10,000 Divisions
2ns up to 20s or 1 to 1,000,000,000 events
±4.1 Divisions
Ext: ±400mV, Ext/10: ±4V
Edge, Glitch, Width, Logic (Pattern), TV (NTSC, PAL, SECAM, HDTV–720p, 1080i, 1080p), Runt, Slew Rate,
Interval (signal or Pattern), Dropout, Qualified (State or Edge)
Measure, zoom and Math Tools
Measurement Parameters
Up to 8 of the following parameters can be calculated at one time on any waveform: Amplitude, Area, Base (Low),
Delay, Delta Period @ Level, Delta Time @ Level, Duty, Duty @ Level, Edge @ Level, Fall Time (90%–10%),
Fall Time (80%–20%), Frequency, Frequency @ level, Maximum, Mean, Minimum, Overshoot+, Overshoot-,
Peak-Peak, Period, Period @ Level, Phase, Rise Time (10%–90%), Rise Time (20%–80%), RMS, Skew,
Standard Deviation, Time @ Level, Top (High), Width+, Width-. Statistics and Histicons can be added to any
measurement and all measurements can be gated.
Use front panel QuickZoom button, or use touch screen or mouse to draw a box around the zoom area.
Functions include Sum, Difference, Product, Ratio, Absolute Value, Averaging (summed and continuous), Derivative,
Envelope, Enhanced Resolution (to 15-bits), Floor, Integral, Invert, Reciprocal, Rescale (change scale and units), Roof,
Square, Square Root, Trend, Zoom and FFT (up to 1 Mpts with power spectrum output and rectangular, VonHann, and
FlatTop windows). 2 dual operator math functions may be defined at a time.
Zooming
Math Functions
14