71M6511/71M6511H
Single-Phase Energy Meter IC
DATA SHEET
AUGUST 2007
Address (hex)
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
Name
IA
VA
IB
-
-
-
TEMP
--
Description
Phase A current
Phase A voltage
Phase B current
Reserved
Reserved
Reserved
Temperature
Reserved
Table 3: CE DRAM Locations for ADC Results
Meter Equations
The Compute Engine (CE) program for residential meter configurations implements the equations in Table 4. The I/O RAM
register
EQU
specifies the equation to be used based on the number and arrangement of phases used for metering. In case of
single-phase metering, the unconnected input should be tied to V3P3A, the analog supply voltage. The
EQU
selection enables
the 71M6511 to calculate single-phase power measurement based on the type of service used. Table 4 also states the
sequence of the multiplexer in the AFE.
EQU
Formula
Channels used from MUX
Sequence
States 0
3
0
1
VA
VA
2
IB
IB
3
-
-
Channels used from alternative
MUX Sequence
States 0
3
0
TEMP
TEMP
1
VA
VA
2
-
IB
3
-
-
000
001
VA IA
(1 element, 2W 1φ)
VA(IA-IB)/2
(1 element, 3W 1φ)
IA
IA
Table 4: Standard Meter Equations (inputs shown gray are scanned but not used for calculation)
Pulse Generator
The CE contains two pulse generators which create low jitter pulses at a rate set by the CE DRAM registers
APULSEW*WRATE
and
APULSER*WRATE
if
EXT_PULSE
(a CE input variable in CE DRAM) is 15. This mode puts the MPU
in control of pulse generation by placing values into the
APULSEW
and
APULSER
registers (“external pulse generation”).
If
EXT_PULSE
is 0,
APULSEW
is replaced with
WSUM_X
and
APULSER
is replaced with
VARSUM_X.
In this mode, the CE
generates pulse based on its internal computation of
WSUM_X
and
VARSUM_X,
the signed sums of energy from all three
elements (“internal pulse generation”).
The
DIO_PV
and
DIO_PW
bits as described in the Digital I/O section can be programmed to route WPULSE and VARPULSE
to the output pins DIO6 and DIO7 respectively. DIO6 and DIO7 can be configured to generate interrupts (useful for pulse
counting by the MPU – see On-Chip Resources (DIO Section).
Page: 12 of 95
© 2005-2007 TERIDIAN Semiconductor Corporation
V2.6