欢迎访问ic37.com |
会员登录 免费注册
发布采购

PLA03151QP8D2 参数 Datasheet PDF下载

PLA03151QP8D2图片预览
型号: PLA03151QP8D2
PDF下载: 下载PDF文件 查看货源
内容描述: 对于开关应用 [For Switching Application]
分类和应用: 开关
文件页数/大小: 8 页 / 360 K
品牌: THINKING [ Thinking Electronic Industrial Co.,Ltd ]
 浏览型号PLA03151QP8D2的Datasheet PDF文件第1页浏览型号PLA03151QP8D2的Datasheet PDF文件第2页浏览型号PLA03151QP8D2的Datasheet PDF文件第3页浏览型号PLA03151QP8D2的Datasheet PDF文件第4页浏览型号PLA03151QP8D2的Datasheet PDF文件第6页浏览型号PLA03151QP8D2的Datasheet PDF文件第7页浏览型号PLA03151QP8D2的Datasheet PDF文件第8页  
CPTC ThermistorPL Series  
For Switching Application  
„ Reliability Test  
Item  
Standard  
Test conditions / Methods  
Specifications  
Fasten body and apply a force gradually  
to each lead for 10±1 sec.  
Terminal diameter  
Force  
T(N)  
5.0  
Tensile Strength  
Of Terminals  
∣△R/R25∣≦20%  
No damage observed  
IEC60068-2-21  
(mm)  
0.35<d0.5  
0.5<d0.8  
10.0  
At least 95% of terminal  
electrode is covered by new  
solder  
Then dip each lead into 255±5solder  
for 3±0.5sec.to the 4±1mm above from body .  
Solderability  
IEC60068-2-20  
IEC60068-2-20  
Resistance to  
Soldering Heat  
Dip each lead into 350±10solder for 34sec.  
∣△R/R25∣≦20%  
No damage observed  
to the 4±1mm above body.  
Fasten body to baseboard with solder perfectly  
and supply since wave oscillation at frequency from  
10 HZ to 55HZ all oscillation with 0.75 mm of  
Vibrato for 24 cycles in each of 3 naturally  
perpendicular plane for a total of 6 hours  
∣△R/R25∣≦20%  
No damage observed  
Vibration  
Shock  
IEC60068-2-6  
IEC60068-2-27  
Putting the PTC product in the shock equipment  
Shock wave: half-sine  
V=1.0m/s;Acceleration:50m/s2 ;Pulse time:30ms  
∣△R/R25∣≦20%  
No damage observed  
-40±3×30min.+85±2×30min ×5Cycles  
excessive time:2minT3min  
∣△R/R25∣≦20%  
No damage observed  
Temp. cycle  
IEC60068-2-14  
IEC60738-1  
+40 ,20%R.H X 24hrs 100 X 16hrs25X 2hrs→  
+40 ,95%R.HX 24hrs0 X 2hrs+40 ,95%R.HX 24hrs→  
25 X (1~2)hrs  
∣△R/R25∣≦20%  
No damage observed  
Climatic sequence  
Endurance at upper  
category temperature  
∣△R/R25∣≦20%  
No damage observed  
IEC60068-2-2  
IEC60738-1  
IEC60068-2-3  
IEC60738-1  
UCT=60, for 1000hrs  
The highest  
temperature and  
max voltage load  
UCT=60, 270VAC, IImax  
∣△R/R25∣≦20%  
No damage observed  
for 1000hrs  
∣△R/R25∣≦20%  
No damage observed  
Humidity  
40±5,90~95%RH,For 1000±2hrs  
Room Temperature  
Intermittent Load  
25±5, 270VAC, IImax  
1min. on and 5min. Off ×10,000 cycles  
∣△R/R25∣≦20%  
No damage observed  
THINKING ELECTRONIC INDUSTRIAL Co., LTD.  
5
www.thinking.com.tw  
2006.07