SN75157
DUAL DIFFERENTIAL LINE RECEIVER
SLLS084C – SEPTEMBER 1980 – REVISED MARCH 1997
electrical characteristics over recommended ranges of supply voltage, common-mode input
voltage, and operating free-air temperature (unless otherwise noted)
†
PARAMETER
VIT
Vhys
VOH
VOL
II
Input threshold voltage (VIT + and VIT –)
Hysteresis voltage (VIT + – VIT –)
High-level output voltage
Low-level output voltage
Input current
VID = 0.2 V,
VID = – 0.2 V,
,
VCC = 0 to 5.5 V,
See Note 4
IO = – 1 mA
IO = 20 mA
VI = 10 V
VI = – 10 V
2.5
TEST CONDITIONS
See Note 3
MIN
– 0.2
– 0.4
70
3.5
0.35
1.1
– 1.6
0.5
3.25
– 3.25
TYP‡
MAX
0.2
0.4
UNIT
V
mV
V
V
mA
IOS
Short-circuit output current§
VO = 0,
VID = 0.2 V
– 40
– 75 – 100
mA
ICC
Supply current
VID = – 0.5 V,
No load
35
50
mA
† The algebraic convention, where the less positive (more negative) limit is designated as minimum, is used in this data sheet for threshold levels
only.
‡ All typical values are at VCC = 5 V, TA = 25°C.
§ Only one output should be shorted at a time and duration of the short circuit should not exceed one second.
NOTES: 3. The expanded threshold parameter is tested with a 500-Ω resistor in series with each input.
4. The input not under test is grounded.
switching characteristics, V
CC
= 5 V, T
A
= 25°C
PARAMETER
tPLH
tPHL
Propagation delay time, low- to high-level output
Propagation delay time, high- to low-level output
TEST CONDITIONS
CL = 15 pF
pF,
See Figure 1
MIN
TYP
15
13
MAX
25
25
UNIT
ns
ns
PARAMETER MEASUREMENT INFORMATION
VCC +
Output
VCC +
0.5 V
Input
51
Ω
tPLH
3.92 kΩ
Output
1.5 V
1.5 V
tPHL
392
Ω
Input
(see Note B)
50%
50%
– 0.5 V
CL = 15 pF
(see Note A)
TEST CIRCUIT
VOLTAGE WAVEFORMS
NOTES: A. CL includes probe and jig capacitance.
B. The input pulse is supplied by a generator having the following characteristics: tr
≤
5 ns, tf
≤
5 ns, PRR
≤
5 MHz, duty cycle = 50%.
Figure 1. Test Circuit and Voltage Waveforms
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265
3