SLVS019F – OCTOBER 1987 – REVISED JULY 1999
timing requirements
VIT+
VIT–
VSU
td
RESET
VOL
td
td
VOH
VCC = 1 V (TYP)
VT
VSO
SCR DRIVE
VOL
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC
(see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 V
Input voltage range, V
I
: 1VSU, 2VSU, 1VSO, and 2VSO (see Note 1) . . . . . . . . . . . . . . . . . . . . –0.3 V to 18 V
Low-level output current (1RESET and 2RESET), I
OL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 mA
High-level output current (1RESET and 2RESET), I
OH
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –20 mA
Package thermal impedance,
θ
JA
(see Notes 2 and 3): DW package . . . . . . . . . . . . . . . . . . . . . . . . . . . 57°C/W
N package . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88°C/W
Lead temperature 1,6 mm (1/16 in) from case for 10 seconds: DW or N package . . . . . . . . . . . . . . . . . 260°C
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values are with respect to the network ground terminal.
2. Maximum power dissipation is a function of TJ(max),
θ
JA, and TA. The maximum allowable power dissipation at any allowable
ambient temperature is PD = (TJ(max) – TA)/
θ
JA. Operating at the absolute maximum TJ of 150°C can impact reliability.
3. The package thermal impedance is calculated in accordance with JESD 51, except for through-hole packages, which use a trace