TK116xxU
TK11650U ELECTRICAL CHARACTERISTICS
Test Conditions: T
A
= 25°C, V
IN
= 6.0 V, unless otherwise specified.
SYMBOL
I
Q
V
OUT
V
DROP
I
OUT
I
OR
I
GND
Line Reg
PARAMETER
Quiescent Current
Output Voltage
Dropout Voltage
Output Current
Recommended Output Current
Ground Current (Note 2)
Line Regulation
TEST CONDITIONS
V
IN
= 6.0 V, I
OUT
= 0 mA
V
IN
= 4.0 V, I
OUT
= 0 mA
V
IN
= 6.0 V, I
OUT
= 10 mA
I
OUT
= 30 mA
I
OUT
= 100 mA
V
IN
= 6.0 V, (Note 1)
V
IN
= 6.0 V
V
IN
= 6.0 V, I
OUT
= 60 mA
V
IN
= 6.0 to 11.0 V
V
IN
= 6.0 V, I
OUT
= 0 to 30 mA
Load Reg
Load Regulation
V
IN
= 6.0 V, I
OUT
= 0 to 100 mA
V
IN
= 6.0 V, I
OUT
= 0 to 150 mA
RR
∆V
OUT
/∆T
Ripple Rejection
Temperature Coefficient
V
IN
= 6.5 V, I
OUT
= 10 mA,
f = 400 Hz, 100 mVrms
V
IN
= 6.5 V, I
OUT
= 10 mA,
-30 ° C
≤
T
A
≤
+80 ° C
2.0
2.0
15
40
120
55
±0.35
4.85
MIN
TYP
400
0.8
5.00
80
17 0
190
150
4.5
30
60
140
220
MAX
800
2.0
5.15
150
330
UNITS
µA
mA
V
mA
mV
mA
mA
mA
mV
mV
mV
mV
dB
mV/° C
Note 1: I
OUT
(Load Current) is current when V
OUT
drops down 0.4 V from V
OUT
at I
OUT
= 10 mA.
Note 2: Refer to “Definition of Terms.”
Page 4
December 1998 TOKO, Inc.