欢迎访问ic37.com |
会员登录 免费注册
发布采购

HSU300-T 参数 Datasheet PDF下载

HSU300-T图片预览
型号: HSU300-T
PDF下载: 下载PDF文件 查看货源
内容描述: 双可选择的AC输入AC - DC 19兼容双 [DUAL SELECTABLE AC INPUT AC-DC 19 COMPATIBLE DOUBLE]
分类和应用: 输入元件
文件页数/大小: 4 页 / 639 K
品牌: TOTAL-POWER [ TOTAL POWER INTERNATIONAL ]
 浏览型号HSU300-T的Datasheet PDF文件第2页浏览型号HSU300-T的Datasheet PDF文件第3页浏览型号HSU300-T的Datasheet PDF文件第4页  
TOTAL POWER INT'L
DOUBLE
DUAL SELECTABLE AC INPUT AC-DC 19" COMPATIBLE
EUROCARD MULTIPLE OUTPUT 250-360 WATTS SWITCHING
MODE POWER SUPPLIES HSU250, HSU300 & HSU360 SERIES
FEATURES:
DUAL INPUT RANGE USER SELECTABLE
DOUBLE OR TRIPLE CONVERTER
ARCHITECTURE
19" COMPATIBLE EUROCARD FORMAT
MEET THE SAFETY STANDARDS
EMI MEET CISPR PUB. 22 & FCC CLASS A
CE MARKING COMPLIANCE
6U X 12HP X 160MM DOUBLE EUROCARD
VMEbus STANDARD
SPECIFICATION
INPUT SPECIFICATION
Input Voltage:
115Vac/230Vac dual selectable.
Input Connector:
DIN 41612 for HSU250/300/360T.
IEC320 AC receptacle for HSU360.
Input Frequency:
47-63Hz
Inrush Current:
Typ. 65A @230Vac.
Input Current:
HSU250 6.0A@115Vac/3.0A@230Vac.
HSU300 1.2A@115Vac/0.7A@230Vac.
HSU360 6.5A@115Vac/3.5A@230Vac.
HSU360T 6.2A@115Vac/3.0A@230Vac.
Dielectric Withstand:
Meet IEC950.
EMI:
Meet CISPR PUB. 22 & FCC Class A.
Power Fail/OK:
Option.
Remote (Logic) Inhibit:
Available.
Hold-up Time:
Typ. 20mS.
Earth leakage:
Typ. 0.3mA @230Vac.
Over Temperature Protection (OTP):
Option.
OUTPUT SPECIFICATION
Output Voltage:
See Ratings Chart.
Output Current:
See Ratings Chart.
Output Wattage:
Typ. 250 Watts for HSU250.
Typ. 300 Watts for HSU300.
Typ. 360 Watts for HSU360/HSU360T.
Output Connector:
DIN 41612 at rear.
Line Regulation:
Typ. 0.4%.
Load Regulation:
VO1 typ. ±1.0%(Main).
VO2 typ. ±1.0%(Main).
VO3 typ. ±1.0%(Main).
or typ. ±3.0%(PR) for HSU360T.
Noise & Ripple:
Typ. 1% peak to peak.
OVP:
Built-in at main VO1/VO2/VO3 (Latch).
Adjustability:
Available at main output VO1,VO2,VO3.
Remote Sense:
Installed at main VO1.
Overload Protection (OLP):
Fully protected against
output overload and short circuit.
Consult factory for OLP setting.
GENERAL SPECIFICATION
Efficiency:
Typ. 75-80.0%.
Operating Temperature:
0 to +50°C at full load. Derates
Switching Frequency:
Typ. 100K Hz.
linearly to +70°C at half load.
Circuit Topology:
Forward circuit.
Storage Temperature:
-20 to +85°C.
HSU250/HSU300/HSU360 triple converter.
Temperature Coefficient:
Typ. 0.04%/°C.
HSU360T dual converter architecture.
Cooling:
At least 60cfm forced air flow is required
Transient Response:
Typ. 3mS following a 25% load change.
for full load.
Power Density:
1.58 Watts / Cubic Inch for HSU250.
Construction format:
12HP(TE)x6Ux160mm
1.90 Watts / Cubic Inch for HSU300.
19” compatible double Eurocard VMEbus standard.
2.28 Watts / Cubic Inch for HSU360 & HSU360T.
Safety Standard:
IEC950/UL1950 Class I.
Note: All measurements are at nominal input, full load, and +25°C unless otherwise specified.