TOTAL POWER INT'L
MAU300
Absolute Maximum Ratings
Exceeding these values can damage the module.These are not continuous operating ratings.
Parameter
Input Surge Voltage
( 1000 mS )
Internal Power Dissipation
5VDC Input Models
12VDC Input Models
24VDC Input Models
Min.
-0.7
-0.7
-0.7
---
Max.
9
18
30
650
Unit.
VDC
VDC
VDC
mW
Environmental Specifications
Parameter
Operating Temperature
Storage Temperature
Humidity
Cooling
Conditions
Min.
-25
-40
---
Typ.
---
---
---
Max.
+70
+125
95
Unit
]
]
%
Free-Air Convection
Model Selection Guide
Model
Number
Input
voltage
VDC
MAU301
MAU302
MAU303
MAU304
MAU305
MAU306
MAU307
MAU311
MAU312
MAU313
MAU314
MAU315
MAU316
MAU317
MAU321
MAU322
MAU323
MAU324
MAU325
MAU326
MAU327
24
(21.6 ~ 26.4)
12
(10.8 ~ 13.2)
5
(4.5 ~ 5.5)
Output
Voltage
VDC
3.3
5
12
15
{5
{12
{15
3.3
5
12
15
{5
{12
{15
3.3
5
12
15
{5
{12
{15
Output
Current
mA (Max.)
500
400
165
133
{200
{83
{66
500
400
165
133
{200
{83
{66
500
400
165
133
{200
{83
{66
Output
Current
mA (Min.)
10
8
3
2.5
{4
{1.5
{1
10
8
3
2.5
{4
{1.5
{1
10
8
3
2.5
{4
{1.5
{1
Input
Current
Max. Load
mA (Typ.)
452
526
495
499
519
504
501
185
212
200
200
210
201
200
92
108
101
101
105
102
100
15
30
60
Input
Current
No Load
mA (Typ.)
Load
Regulation
% (Max.)
11
11
7
7
10
7
7
8
8
5
5
8
5
5
8
8
5
5
8
5
5
Efficiency
% (Typ.)
73
76
80
80
77
79
79
74
78
82
83
79
82
82
74
77
81
82
79
81
82
Specifications typical at Ta=+25],resistive load,nominal input voltage,rated output current unless otherwise noted.
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: sales@total-power.com http://www.total-power.com
-2-